In case you want more information about the controllers and accessories, please refer to the Controller and
Accessory TDB on pvi.Samsung.com site or Global Partner Portal site.
11. Installation
2
the selected location, at a 15° downward angle so
that the drain hose will drain properly.
Drain hose
Wall
Indoor unit
3
Left
Right
Rear right or left
NOTE
•
Connecting the power and communication cables
WARNING
•
electrical installations and the wiring regulations in
the local area.
•
ground the appliance to a gas pipe, plastic water
1
Before
connecting
Correct
Upside
down
Non-
circular
After
connecting
Correct
Correct
Upside
down
Non-fitted
Indoor Unit Installation
Model
**09*******
**12*******
Power cable
(Outdoor unit)
3G X 2.5 mm²,
H07RN-F
Outdoor-to-indoor
power cable
3G X 1.0 mm²,
H07RN-F
Communication
cable
2 X 0.75 mm²,
H05RN-F
Type GL
16A