58
Ⅳ.ADJUSTMENT
5) SHUTTER CLOSE TIME ADJ
After changing the MAIN PCB, BARREL and CCD, adjust the SHUTTER CLOSE TIME.
Required Equipment: AE TESTER(LV 15.8±0.1.)
< How to adjust >
a...Prepare AE TESTER that can be test up to LV 15.8±0.1.
b...Attach the camera to the AE TESTER.
c...Set the LV to 15.8±0.1.
d...Download the program and save it to SD memory card
e...Insert the SD memory card that has the program file and
turn on the camera.
f... The adjustment will be done automatically.
g... After completing the upgrade, the camera is turned off automatically.
ҭIf the adjustment is incomplete, <Figure 5-2> will display. In this case, re-try the adjustment process.
<Figure 5-1>
<Figure 5-2>

Other manuals for Samsung DIGIMAX S1000