Ass’y Duct Heater (Electric)
Ass’y Duct (Gas)
Ass’y Fan
F0005 = DC47-00017A
A0369 = DC47-00015A
F0005 = DC47-00018A
Thermistor W0035 = DC32-00007A
F0005 = DC47-00016A
CN1
1 120vac N (Brn)
2 Sub PCB (Wht)
3 Sub PCB (Yel)
Relay 1
1 Motor Belt Sw (Brn)
2 120vac L1 (Blk)
Relay 6
1 Gas Hi Limit T-Stat (Blu)
2 120vac L1 (Blk)
Relay 6
1 Heater Cut Off T-Stat (Blu)
2 120vac L1 (Blk)
CN5
1 Lamp (Vio)
CN6
1 Earth Ground (Grn)
CN4
3-6 Thermistor (Blu-Red)
4-5 Moisture Sensor (Pnk-Org)
CN2 Sub PCB Display
5-4 5VDC (Wht-Pnk)
6-4 15VDC (Red-Pnk)
CN7
1 Motor #6 (Blk)
2 Door Sw (Blu)
New Version of
Blower Housing, it
may be necessary to
separate the harness
wrap on replacement
housing. Please
maintain shielding
on the low voltage
wires.