4-2
4. Troubleshooting
4-1-1. No Power
Symptom
The LEDs on the front panel do not work when connecting the power cord.
The SMPS relay does not work when connecting the power cord.
The units appears to be dead.
-
-
-
Major
checkpoints
The IP relay or the LEDs on the front panel does not work when connecting the power cord if the cables are
improperly connected or the Main Board or SMPS is not functioning. In this case, check the following:
Check the internal cable connection status inside the unit.
Check the fuses of each part.
Check the output voltage of SMPS.
Replace the Main Board.
-
-
-
-
Diagnostics
Caution
Make sure to disconnect the power before working on the SMPS/IP.
Does proper DC 3.3V appear at C1013?
Check a IC1011
Change a main PCB ass’y
No
Yes
Does proper DC 5V, 2.5V, 1.2V appear
at C1051, C1057, C1066?
No
Yes
LAMP off, power indicator
LED red color?
Yes
No
Check a connection a power cable.
Does proper DC 13V appear at
pin2 of CN1001?
No
Yes
A power is supplied to set?
Change a Assy PCB Power.
Check a IC1022, IC1021, IC1006.
Change a main PCB ass’y.