4-2
4. Troubleshooting
Simple ow chart of malfunction
Yes
No
Yes
Does the TV turn on?
Can you see anything
on the screen?
Yes
Can you see OSD menu
running on the screen?
Check LVDS cable connected
to Main Board.
If necessary,
replace the Main Board
Yes
Can you see Digital
Channel broadcast ?
Yes
Replace the Main Board
Check the Power Cord
Yes
No
No
Is standby LED on?
Yes
A5V appear at the pin
27 of CN201?
Yes
is any sound of TV?
Yes
Check dimming cable.
If necesary replace the
Main Board.
Yes
Check 30p cable.
If necessary, replace the
IP board.
Yes
B13V appear at the pin
9 or 10 of CN201?
Yes
Change the main board.
Please, contact Tech support