Operating Instructions and Installation
Samsung Electronics3-6
3-2-2(a) Fixing the Installation Plate
3-2-2(b) Purging the Unit
Installation plate
Pipe hole
(ø65mm)
1. Determine the position of the pipe and drain hose
hole using the right figure and drill the hole with an
inner diameter of 65mm so that it slants slightly
downwards.
2. If you are fixing the indoor unit to a… Then follow
Steps…
Wall 3.
Window frame 4 to 6.
3. Fix the installation plate to the wall in a manner
appropriate to the weight of the indoor unit.
If you are mounting the plate on a concrete wall
with anchor bolts, the anchor bolts must not project
by more than 20mm.
4. Determine the positions of the wooden uprights to
be attached to the window frame.
5. Attach the wooden uprights to the window frame in
a manner appropriate to the weight of the indoor
unit.
6. Using tapped screws, attach the installation plate to
the wooden uprights, as illustrated in the last figure
opposite.
On delivery, the indoor unit is loaded with an inert
gas. All this gas must therefore be purged before
connecting the assembly piping. To purge the inert gas,
proceed as follows.
Unscrew the caps at the end of each pipe.
Result : All inert gas escapes from the indoor unit.
• To prevent dirt or foreign objects from getting
into the pipes during installation, do NOT
remove the caps completely until you are ready
to connect the piping.
410~730
(Unit : mm)
(Unit : mm)
DB98_06187A(2)_1 2/19/03 2:50 PM Page 2-10