Samsung MH18ZC1(C2)-09 - Refrigerating Cycle Block Diagram

Samsung MH18ZC1(C2)-09
67 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-7Samsung Electronics
2-3 Refrigerating Cycle Block Diagram
2-3-1 MH18ZC1(C2)X / MH19ZC1(C2)X / MH24ZC1(C2)X
STD Pressure Piping Temp.(˚C) Temp. Condition (˚C)
Operating Condition (kg/cm
2
G)
T1 T2
Indoor Outdoor
3-way valve DB WB DB WB
Standard 5.0~5.2 11 10 27 19 35 24
A or B Max over load 5.4~5.6 17 16 32 23 43 26
Cooling
Low temp. 3.5~3.7 4 3 21 15 21 15
Standard 5.0~5.2 12 10 27 19 35 24
A + B Max over load 5.4~5.6 17 16 32 23 43 26
Low temp. 3.5~3.7 4 3 21 15 21 15
Standard 17~19 38 59 20 15 7 6
A or B Max over load 19~25 56 49 27 19 24 18
Heating
Deice - - - 20 12 2 1
Standard 17~19 33 55 20 15 7 6
A + B Max over load 19~25 56 48 27 19 24 18
Deice - - - 20 12 2 1
INDOOR UNIT OUTDOOR UNIT
Capillary tube
Capillary tube
Heat
exchanger
(Condenser)
4Way valve
3Way valve
2Way valve
Compressor-B
Compressor-A
Gas side
Liquid side
Cross fan
Cross fan
Propeller fan
T2
T1
(A) (B)
Check valve
Cooling
Heating
Gas leak
check point
Heat
exchanger
(Evaporator)
Refrigerating cycle temperature and pressure