Operating Instructions and Installation
Samsung Electronics3-6
3-2-1(b) MH18ZC1(C2)-09 / MH19ZC1(C2)-07 / MH26ZC1(C2)-07
Cooling Characteristics - Outdoor Temperature
Test Condition Indoor Unit(DB/WB) : 27/19
Voltage/Frequency : 240V/50Hz
Cooling Capacity(Btu/h)
Air Outlet
Temperature(DB)
10000
Cooling Capacity
Outdoor Temperature(DB/WB)
21/15
35/24
43/26
Air Outlet Temp.
7000
8000
9000
15
14
13
12
11
10
Low Pressure(kg/cm
2
)
Cooling Capacity Low Pressure
Cooling Capacity(Btu/h)
10000
Outdoor Temperature(DB/WB)
21/15 35/24 43/26
7000
8000
9000
7
8
4
3
5
6
Cooling Capacity & Air Outlet Temperature
Cooling Capacity & Low Pressure