4.Troubleshooting
Diagnostics>Fax>NVMRead/Write
Thismenuchangesacongurationvalueforfax.
CodeNameDescriptionDefaultRange
20-200PauseDialTimePauseTime(value*1000ms)Country
Value
0~200
20-210DialPul.M/B33/6640/60Country
Value
0=OPTION_DP_33
1=OPTION_DP_40
2=OPTION_DP_37
3=OPTION_DP_50
20-220AutoDialP-TimePausetimebeforeauto-dialing(second)10~10
20-300RingOnTimeRingOnTime(ms)17090~800
20-310RingOffTimeRingOffTime(ms)56090~800
20-320RingDet.FreqsetstheCallIndicationfrequencyrange
thatwillbedetectedbyLIU
11=12-80hz
2=16-55hz
3=20-55hz
4=22-55hz
20-330RingOnMaxTimeRingOnMaxTime(ms)51003000~12000
20-340RingOffMaxTimeRingOffMaxTime(ms)111009000~22000
20-400DTMFH-FreqLvDTMFHigh-Freq.Level(dBm)Country
Value
0~15
20-410DTMFL-FreqLvDTMFLow-Freq.Level(dBm)Country
Value
0~15
20-420DTMFTimingDTMFdurationofon/offoutput(Ms)81=80/80
2=70/70
3=70/150
4=60/60
5=80/100
6=150/50
7=150/240
8=100/100
9=100/80
20-500DialModeSelectTone/PulseCountry
Value
0=OPTION_TONE
MODE
1=OPTION_PULSE
MODE
20-520ErrorRateAdjustErrorRate(Off/5%/10%/20%)20=OPTION_RATE
OFF
1=OPTION_RATE
5
2=OPTION_RATE
10
3=OPTION_RATE
20
20-530DialtonedetectdetectdialtonepriortosendingCountry
Value
0=OPTION_OFF
1=OPTION_ON