EasyManua.ls Logo

Samsung RF4287HARS - If FAN Does Not Operate(Flex Room - FAN)

Samsung RF4287HARS
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
82
TROUBLESHOOTING
- This refrigerator has BLDC FAN motor. BLDC motor is driven by DC10~12V
- When COMP ON, normally with F-FAN motor.
4-2-4. If FAN does not operate(Flex Room - FAN)
Start
Execute manual operation
No
Yes
Yes
No
Yes
Yes
No
No
Is COMPRESSOR ON ?
Is the Flex
Room temperature suitable for
the Fan working?
Predicted Cause
FAN-MOTOR troubles itself
Bad wiring connections.
Wrong Input of the fan motor rotation pulse
Is the voltage between
CN79-"1"(Orange) and "3"(Blue)
(Black) around DC10~12V?
Does DC7~12V alternate
with below DC2V between CN79-
"1"(Orange) and "3"(Blue)
FAN works normally
Operation
temperature/ready
Replace MAIN PCB
Flex Room control temperature
Sort
Micom
(IC01)
Initial
power On
Heater
off
Working
heater
37
(3)
42
(6)
27
(-3)
32
(0℃)
Temperaure
Checking method of Flex Zoon FAN Motor Voltage with the voltage
between CN79-"1"(Orange) and "3"(Blue) shall be less than DC10~12V
- Additional check if resistance values are different after measurement.
1) Flex Room - FAN
AW3 SM-EN 2011.3.31 2:56 PM 8 2 i n

Table of Contents

Other manuals for Samsung RF4287HARS

Related product manuals