TROUBLESHOOTING
2) If ICE Maker(F) Sensor has troubled
Bad contact of connector/ insert correctly
Is MAIN PCB
Connector CN90 inserted
correctly?
Is ICE Maker(F)
sensor unit normal?
Is the voltage between
MAIN PCB Connector CN90#"4"(White)
and REG1, HEAT SINK normal?
Is input voltage of
IC01 MICOM #78 normal?
Start
NO
YES
YES
YES
YES
Replace the ICE Maker
NO
Check the contact of PCB & Wire
Terminal correctly.
NO(0.6V > Measurement < 4.6V)
Check the iced-solder, solder bridging,
disturbed solder.
Replace the PCB
This refrigerator has Dual Ice Maker,
so controlled two Ice Makers.
NO
No trouble with PCB and temperature sensor.
Recheck the bad contact of the connection.
** Measuring point of resistance value according to Sensor **
ICE MAKER(F) : CN90 #3 or #8 #4 measuring
resistance value
** 0: Short trouble / ∞Ω: Open trouble
Sensor MICOM/Connector number
Voltage measured between 4.6V ~ 0.6V.
Measuring voltage of IC01 MICOM #78,
CN90#4(White) and REG1, HEAT SINK from PCB
typical Ground part are similar.
Check the measure on the SENSOR MARKING #9(R901)
due to the SMD MICOM.
Checking Method of ICE MAKER(R) Senser
resistance CN90 #3(white) or #8(Sky_blue)
#4(White)
- Compare the temperature table after the measure.
DATA1.
Temperature table
ERROR Code
Refer to circuit diagram in the manual
ICE
Maker(F)
Connector CN90-#4(White) and REG1
HEAT-SINK PCB common Ground
Checking method of ICE Maker(F) Sensor voltage
- Measure the voltage of Sensor Check Point #9(IC01 MICOM
#78) or CN90#4(white) REG1, HEAT SINK.
- Compare the temperature table after the measure.
Measuring voltage of CN90#4(White) REG1, HEAT SINK
are below.
typical PCB Ground
REG1 HEAT-SINK
66