Load mode Check list
NO Part Display (LED) Operation contents
1 R-FAN HIGHEST R-1-
ⓐ
,
ⓑ
When R-FAN HIGHEST operates, applicable LED blinks.
2 R-FAN HIGH R-1-
ⓐ
When R-FAN HIGH operates, applicable LED blinks.
3 R-FAN LOW R-1-
ⓑ
When R-FAN LOW operates, applicable LED blinks.
4 R-DEF HEATER R-1-
ⓒ
When R-DEF Heater operates, applicable LED blinks.
5 Overload condition R-1-
ⓔ
When ambient temperature is more than 93°F(34°C),LED blinks.
6
Low Temperature
condition
R-1-
ⓕ
When ambient temperature is less than 70°F(21°C),LED blinks.
7 Normal condition
R-1-
ⓔ
,
ⓕ
(Not blinks ALL LED)
When ambient temperature is between 72°F(22°C) and 91°F(33°C).
8 Exhibition mode R-1-
ⓖ
LED Blinks at the display mode.
9
ICE MAKER FULL
(DISPENSER model)
R-10-
ⓓ
When the Ice Maker's Bucket is full, applicable LED blinks.
10 COMP F-1-
ⓐ
When COMP operates, applicable LED blinks.
11 F-FAN HIGHEST F-1-
ⓑ
,
ⓒ
When F-FAN HIGHEST operates, applicable LED blinks.
12 F-FAN HIGH F-1-
ⓑ
When F-FAN HIGH operates, applicable LED blinks.
13 F-FAN-LOW F-1-
ⓒ
When F-FAN LOW operates, applicable LED blinks.
14 F-DEF HEATER F-1-
ⓓ
When F-DEF HEATER operates, applicable LED blinks.
15 C-FAN HIGHEST F-1-
ⓔ
,
ⓕ
When C-FAN HIGHEST operates, applicable LED blinks.
16 C-FAN HIGH F-1-
ⓔ
When C-FAN HIGH operates, applicable LED blinks.
17 C-FAN LOW F-1-
ⓕ
When C-FAN LOW operates, applicable LED blinks.
18 F-VALVE F-10-
ⓑ
When F-VALVE opens, applicable LED blinks.
19 R-VALVE F-10-
ⓒ
When R-VALVE opens, applicable LED blinks.
20 DISPENTER HEATER F-10-
ⓔ
When DISPENSER HEATER operates, applicable LED blinks.
21 DAMPER F-10-
ⓕ
When DAMPER opens, applicable LED blinks.
22 WIFI Status WIFI Icon
When AP and Internet Disconnect : LED OFF.
When AP connect and Internet Disconnect : LED Blinks.
When AP and Internte connect : LED ON.