16
This document cannot be used without Samsung's authorization
PRECAUTIONS(SAFETY WARNINGS)
Items
Specification
Model
RS68N8220**
RS68N8320**
RS67N8210** RS66N8100**
RS68N8221**
RS68N8331**
RS67N8211** RS66N8101**
RS68N8222**
RS68N8232**
RS68N8242**
RS68N8322**
RS6GN8222**
RS6GN8322**
RS6GN8332**
Electric Component
Defrosting heater in
freezing compartment
Power supplying during
freezing compartment
defrosting
AC230V,200W or AC120V,200W
Defrosting heater in
cold compartment
Power supplying during
cold compartment defrosting
-
Home bar heater
(cold compartment)
Ambient humidity sensor
interlocking
-
Icemaker heater
-
Dispenser heater
AC 230V,6W or
AC120V,6W
-
AC 230V,6W or
AC120V,6W
-
AC 230V,6W or
AC120V,6W
Water pipe heater
DC12V 6W DC12V 2.3W - DC12V 6W DC12V 2.3W - DC12V 6W
Water tank heater
-
Damper heater Kept tumed on
-
Bimetal for preventing overheating of
defrosting heater in freezing compartment
Thermostat (BT-121-M) On: 40°C, Off: 60°C
Bimetal for preventing overheating of
defrosting heater in cold compartment
-
OLP
Type
-
Operating temperature
(°C)
-
Shutdown temperature
(°C)
-
Cooling fan motor in freezing compartment
DC12V, AIO Q7
Cooling fan motor in cold compartment
DC12V, AIO Q7
Compressor cooling fan motor
DC12V, C150Q
Motor-driven damper
(True-taste chamber)
-
Motor step valve
DC 12V,700mA
DC valve
DC 12V,
300mA
(RS68N8320**)
- -
DC 12V,
300mA
(RS68N8331**)
- -
DC 12V,
300mA
(RS68N8322**/
RS6GN8322**/
RS6GN8332**)
Freezing compartment lamp
DC12V, MAX 2.39W, 1EA
Cold compartment lamp
DC12V, MAX 4.22W, 1EA
Fridge Door Lamp
-
Door reed switch
DC 200V 0.5A
Power cord
AC 250V 10A or 16A
Grounding screw
BSBN(BRASS SCREW)