EasyManua.ls Logo

Samsung RT22 - Final Setup Procedures

Samsung RT22
75 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15
PRODUCT SPECIFICATIONS
MODEL RT38(RT42), RT35(RT39), RT32(RT36), RT29(RT33), RT25(RT28), RT22(RT26)
Temperature
Freezer
Type Temperature Selection ON (℃)
OFF (℃)
F-Sensor Not applied - -
Refrigerator
R-Sensor
Dispaly bar
type(5steps)
Actual set
temperature
Rotary type(6steps)
Actual set
temperature
7℃
6.5±2℃
1 step 6.5±2℃
5℃
5.0±2℃
2 step 5.0±2℃
3℃ 3.0±2℃ 3 step 3.0±2℃
2℃ 2.0±2℃
4 step 2.0±2℃
5 step 1.0±2℃
1℃
0.5±2℃
6 step 0.5±2℃
Electrical parts
Defrosting
First Defrost Cycle
Not applied
Defrost Cycle Min(6HR), Max(53HR)
Pause Time 10 Min
Sensor
Refrigerator-Sensor
THERMISTOR(PX-41C, 502AT-2)
SPEC (5.0KΩ/25℃)
Freezer Evap-Sensor
Ambient TEMP-Sensor
MODEL RT38(RT42), RT35(RT39) RT32(RT36), RT29(RT33) RT25(RT28), RT22(RT26)
Temperature
RATED INPUT
110~127V/60Hz
220V~240V/50~60Hz
󱈔󱈔
COMPRESSOR
MODEL
MSV488AL1R / MSV488AL1P
󱈔󱈔
[ ISO Energy ] A+(RT**F**A**, RT**F**D**): MSV488AL1R / A++(RT**F**C**): MSV488AL1P
Overload Protector 4TM308RFBYY-82 󱈔 󱈔
Motor Fan
3612JL-04W 󱈔 󱈔
3350 ±7% 󱈔 󱈔
1.92W 󱈔 󱈔
92mm/3wing 󱈔 󱈔
Electrical parts
Lamp LED Type FR4, 65*10, 1.6T, 3PKG 󱈔 󱈔
Heater-Defrost
120V, 160W, 90ohm,
230V, 160W, 330ohm
120V, 130W, 110ohm,
230V, 130W, 407ohm
120V, 120W, 120ohm,
230V,120W, 440ohm
Metal Sheath Heater 󱈔 󱈔
Door-Switch
125VAC/1.5A
250VAC/0.75A
1-BUTTON
󱈔󱈔
pump Motor DC12V, 400mA(Optional) 󱈔 Not applied
Switch for water AC 250VAC 16A(Optional) 󱈔 Not applied
MOTOR – ANTI VIRUS PROTECTOR DC12V, 70mA(Optional) Not applied Not applied
Water valve DC12V,300mA(Optional) 󱈔 Not applied