2. Temperature control function
1) Temperature selection of freezer compartment
❈ After the initial key selection, it displays the notch which is presently set up, then within 5
seconds re-memorize the key after 1-2) points mentioned below. If there is no input of the
key, it moves back to the previous temperature display.
1-1) From -14
˚C
~ -25
˚C
, each one key is selected in 1
˚C
interval.
1-2) Selection key operation for Freezer is set up orderly.
1-3) Actual temperature is indicated during both Power-On and electrical failure.
1-4) Standard temperature of each stage is as follows.(standard for 1/3 height)
1-5) After key input, seven-segment indication changes immediately but actual function
operates after 10seconds.
2) Temperature selection of refrigerator compartment
2-1) From 7
˚C
~ 1
˚C
, each one key is selected in 1
˚C
interval.
2-2) After the initial key selection, the former selected temperature is displayed, and within
5seconds temperature selection alters as in 2-3), and when final key input is done, the
final key input temperature converse into a set point after 10 seconds.
2-3) Set up is established orderly according to operation of selection button.
2-4) Actual temperature is indicated during both Power-On and electrical failure.
2-5) Standard temperature of each stage is as follows.(standard for 1/3 height)
2-6) After key input seven-segment indication changes immediately but actual function
operates after 10seconds.
Stage
Temperature
123456789101112
-14˚C -15˚C -16˚C -17˚C -18˚C -19˚C -20˚C -21˚C -22˚C -23˚C -24˚C -25˚C
Stage
Temperature
1234567
7˚C6˚C5˚C4˚C3˚C2˚C1˚C