EasyManua.ls Logo

Samsung SR-S20DTC - Page 20

Samsung SR-S20DTC
105 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7-6)
Test
Function
Ree
Sabet
ee
a
ee
PS
i
Pe
TE
@
Test
function
is
for
test,
process
inspection
and
SVC
of
PCB
and
product.
e
After
selecting
test
S/W
and
confirming
function
of
product,
turn
on
power
switch
again
to
operate
self-inspection
function.
®
if
you
press
Quick
Freezer
Key
on
Display
Panel
and
temperature
control
Key
in
R-room
for
more
than
8
seconds,
all
Displays
will
be
turned
off
and
continue
operating
in
Test
Mode.
At
this
moment,
if
any
key
is
pressed
among
freezer
temperature
control
key,
Refrigerator
temperature
control
key,
quick
freeze
key
or
vacation
key,
it
operates
as
the
test
button.
,
+
F-room
:
Freezer,
R
room
:
Refrigerator
Forced
Operating
Function
1)
In
the
state
where
display
panel
was
converted
into
test
mode,
if
test
button
is
selected
once,
COMP
will
operate
immediately
without
5
minute
delay
function.
Therefore,
forced
operation
is
conducted
at
the
very
moment
of
COMP
OFF,
over
load
may
be
caused.
Please
be
careful.
2)
If
forced
operation
is
selected,
freezer
and
Refrigerator
is
set
to
automatic,
and
the
temperature
of
freezer
is
set
to
“-26°C”
and
Refrigerator
is
set
to
“14°C”,
Comp
and
F-fan
operates
continuously,
and
R-fan
in
Refrigerator
is
controlled
by
“1°C”
setup.
3)
Forced
operation
is
valid
for
24hrs.
That
is,
if
24hours.
pass
after
selecting
forced
operation,
simultaneous
defrost
in
both
Refrigerator
and
freezer
is
automatically
carried
out.
And
normal
operation
is
carried
out
by
present
setup
of
Refrigerator
and
freezer.
4)
Cancellation
of
forced
operation
in
the
middle
of
working
is
possible
by
turning
on
Power
after
turning
it
off
(resetting),
or
by
selecting
test
cancel
mode
shown
in
the
item
3
below.
5)
When
forced
operation
works,
alarm
sound
will
continue
until
forced
operation
is
completed.
There
is
no
alarm
cancel
function.
@
Forced
Defrost
Function
1)
In
the
state
of
forced
operation,
if
display
panel
is
converted
into
test
mode
and
press
the
test
button
once
more,
forced
operation
is
cancelled
immediately,
and
evaporator
defrost
function
of
Refrigerator
operates.
2)
At
this
time,
beep
alarm
sounds
for
3sec.
at
the
point
of
defrost,
and
0.75sec.
ON/0.25sec.
off
sound
occurs
during
forced
defrost
function
of
Refrigerator
works.
3)
If
above
defrost
function
of
Refrigerator
is
maintained,
it
operates
normally
after
defrost
is
completed.
4)
While
forced
defrost
function
of
Refrigerator
operates,
pressing
the
test
button
once
more
enables
simultaneous
defrost
for
both
freezer
and
Refrigerator.
5)
At
this
time,
beep
alarm
also
sounds
for
3sec.
at
the
point
of
defrost,
and
0.75sec.
ON/
0.25sec.
off
sound
occurs
continually
until
simultaneous
defrost
of
F
and
R
is
completed.
Test
Cancel
Mode
1)
In
the
state
of
simultaneous
defrost
of
freezer
and
Refrigerator,
if
display
panel
is
converted
into
test
mode,
and
test
button
is
pressed
once
more,
defrost
of
both
freezer
and
Refrigeration
is
cancelled
immediately
and
resumes
normal
operation
.
%*
Reference
It
works
step
by
step
in
test
function.
It
does
not
change
from
1
step
(forced
operation)
to
4
step
(test
cancel
mode)
directly.
It
operates
corresponding
function
only
after
it
goes
through
the
previous
step.
While
test
function
works,
it
is
most
desirable
to
turn
off
main
power
and
then
turn
it
on.

Related product manuals