EasyManua.ls Logo

Samsung SR-S20DTC - Door Switch & Ice Lever Switch Check

Samsung SR-S20DTC
105 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Reference
No.
5)
Check
Door
S/W
Fault
&
Ice
Lever
S/W
Check
Method
)
|
Check
in
state
that
power
is
applied.
|
Door
S/W
is
2
contact-point
circuit;
|
one
contact-point
senses
door
|
open/close
with
DC
5V
on
PCB,
and
|
the
other
contact-point
lets
refrigerator
inside
lamp
fluorescent
On/Off.
FROM
POOR
ce
azven
sw
|
ao
(R-Room
Lamp
Part)
1.
When
refrigerator
door
is
opened,
check
whether
lamp
is
lit
up
or
not.
If it
is
normal,
check
whether
lamp
lights
out
or
not
when
pressing
DOOR
S/W
in
the
state
that
R-
DOOR
is
open.
If
any
faults
are
found,
check
DOOR
S/W
of
R-ROOM
door.
(MAIN-PCB
Sensing
Part
for
R-ROOM
Door
Open
)
1.Check
voltage
by
applying
“+”
terminal
to
CN30
and
“-”
terminal
to
.
2.
When
R-ROOM
door
is
opened,
if
about
DC
5V
is
measured,
it
is
normal.
3.
When
R-ROOM
door
is
closed,
if
about
DC
OV
is
measured,
it
is
normal.
If
any
faults
are
found,
check
DOOR
S/W
and
wire
connection
system.
(F-Room
Lamp
Part)
1.
When
freezer
door
is
opened,
check
whether
lamp
is
lit
up
or
not.
If
it
is
normal,
check
whether
lamp
lights
out
or
not
when
pressing
door
S/W
in
the
state
that
F-DOCR
is
open.
If
any
faults
are
found,
check
door
S/W
of
F-ROOM
door.
(MAIN-PCB
Sensing
Part
for
F-ROOM
Door
Open
)
1.Check
voltage
by
applying
“+”
terminal
to
CN30
and
“-”
terminal
to
.
2.
When
F-ROOM
door
is
opened,
if
about
DC
5V
is
measured,
it
is
normal.
3.
When
F-ROOM
door
is
closed,
if
about
DC
OV
is
measured,
it
is
normal.
If
any
faults
are
found,
check
DOOR
S/W
and
wire
connection
system.
(ice
Eject
Lever)
1.
In
case
ice
is
not
ejected
though
ice
eject
lever
which
is
installed
at
the
front
part
of
freezer,
check
like
the
following.
2.
First,
check
fault
existence
of
F-ROOM
DOOR
SM.
If
no
defect
is
found,
separate
CN31
connector
on
the
MAIN-PCB.
Apply
“+”
terminal
to
and
“-”
terminal
to,
and
check
resistance.
Check
it
becomes
0
2
when
ICE
LEVER
S/W
was
pressed.
When
it
is
always
oo
regardless
of
ON/Off
of
S/W,
check
wire
system
and
connection
system.