3.
ice-making
function
@
Ice-making,
which
operates
until
the
finish
of
ice-making
in
ICE-TRAY
after
water
supply,
issensed
by
the
temperature
sensed
by
Ice-Maker
Sensor
(may
be
changed
by
OPTION).
1)
Check
the
temperature
of
Ice-Maker
Sensor
90
minutes
after
water
is
supplied
to
Ice-Tray.
2)
When
-10°C_
continues
to
be
sensed
by
Ice-Maker
Sensor
for
more
than
5
minutes,
ice-making
is
perceived
to
be
finished.
4.
Eject
function
@
Eject
function
is
to
dispense
the
made
ice
in
the
ICE-TRAY
after
the
finish
of
ice-making.
1)
At
first,
ON/OFF
state
of
LEVER
S/W
is
checked
to
CHECK
whether
the
Ice-Tray
is
in
Full
ice
horizontality.
When
LEVER
S/W
is
in
ON
state
(MICOM
PIN
#5001"“LOW’
),
indicating
thie
Full
ice
horizontality,
Eject
does
not
operate
and
is
in
stand-by.
Eject
starts
to
operate
20
minutes
after
the
change
of
ON
to
OFF
of
LEVER
S/W.
2)
If
it
is
not
the
Full
ice
horizontality
(LEVER
S/W
OFF
=
MICOM
PIN
NO
#50
“HIGH”),
Eject
operation
starts
immediately.
At
this
time,
the
Eject
operation
dispenses
ice
from
the
Ice-Tray
by
rotating
clockwise
the
Eject
Motor
and
then,
twisting
the
Ice-Tray
to
the
maximum.
By
the
Eject
operation,
Check-Ice
Lever
performs
automatically
the
ascending
operation.
3)
The
maximum
twisted
state
is
sensed
by
the
operation
of
HOR/INVERTER
S/W
and
LEVER
S/W.
In
Eject
condition
with
horizontality,
HOR/INVERTER
S/W
and
Check-Ice
are
all
OFF
and
Eject
operates
by
rotating
clockwise
Eject
Motor.
While
Eject
Motor
is
operating,
HOR/INVERTER
S/W
is
changed
from
OFF
to
ON
after
about
1
second
and
LEVER
S/W
is
changed
to
ON
after
about
3.3
seconds.
When
LEVER
S/W
is
not
changed
to
ON
even
after
6
seconds,
problems
with
MOTOR
or
LEVER
S/W
are
perceived
and
so,
Eject
operation
stops
to
return
to
the
horizontality.
4)
When
LEVER
S/W
is
ON
at
the
time
that
HOR/INVERTER
S/W
is
changed
to
OFF
from
ON
15
seconds
before
the
start
of
clockwise
operation
of
Motor,
it
is
the
maximum
twisted
point.
When
HOR/INVERTER
S/W
is
not
changed
to
OFF
from
ON
even
after
15-second
operation
of
Motor,
problems
with
HOR/INVERTER
S/W
or
MOTOR
are
perceived
and
Eject
operation
stops
to
retum
to
the
horizontality.
5)At
the
time
of
the
maximum
twisted
state
of
the
Ice-Tray,
operation
stops
for
2
seconds.
6)
Counter
clockwise
rotation
of
Eject
Motor
makes
the
Ice
Tray
return
to
the
horizontality.
At
this
time,
Check-Ice
Lever
descends
to
sense
the
storage
state
of
ice.
7)
On
the
horizontality,
Cycle
of
Water
Supply
Ice-Making
Eject
Return
to
horizontality
repeats.
a
Timing
Chart
of
Eject
Operation
|
Maximum
Twisted
Point
ue
Delay
time
(2
seconds)
1
Return
ti
Sis
horizontli
ty
t

Other manuals for Samsung SR-S25NTA