5.
TEST
function
@
This
is
for
the
case
of
the
Forced-Operation
for
the
purpose
of
Operation
TEST,
A/S,
and
Cleaning
and
TEST
function
operates
when
TEST
S/W
implemented
with
the
Ice-Maker
itself
is
pushed
for
more
than
1.5
second.
;
1)
TEST
function
does
not
operate
in
the
case
of
the
Eject
operation,
Horizontality
Noise,
Water-
Supply
Operation,
and
Full
Ice
state.
The
function
operates
only
in
the
case
of
horizontality
and
OFF
of
Lever
S/W
after
cancellation
of
Full
Ice.
2)
With
the
horizontality,
by
pushing
TEST
button
for
more
than
1.5
second,
Eject
operates
immediately
regardless
of
the
ice-making
condition
in
the
Ice-Tray.
So,
when
the
water
is
not
frozen
and
TEST
function
is
operated,
water
will
be
poured
out.
After
Eject
operation
and
with
Horizontality
noise
operation,
1
CYCLE
of
water-supply
operates.
Therefore,
Eject
operation,
Horizontality
operation,
and
trouble
with
water-supply
can
be
checked
by
TEST
button.
If
TEST
function
operates
normally,
“Ding-Dong”
sounds
and
water-supply
function
operates.
So,
if
there
is
no
“Ding-Dong”
sounds,
check
and
repair
should
be
performed.
3)
On
the
finish
of
water-supply,
normal
CYCLE
of
Ice-making
Eject
Return
to
Horizontality
>
Water-supply
operates.
<Cases
when
TEST
function
does
not
operate>
When
Eject,
Horizontality
noise,
or
Water-supply
is
operating,
after
the
finish
of
the
operation.
02
On
Full
Ice
|
After
removal
of
ice
in
the
Ice-Tray
Check-Ice
Lever
ON-»
OFF
6.
Function
by
F-Room
DOOR
OPEN
@
This
is
to
minimize
the
noise
by
stopping
the
operation
when
F-Room
DOOR
opens.
1)
When
F-Room
Door
opens
during
the
operation
of
Eject
or
Horizontality
noise,
operation
stops
immediately
at
that
time.
With
the
door
closed,
normal
operation
starts
again.
2)
While
water
is
supplying,
normal
operation
continues,
regardless
of
F-Room
DOOR
OPEN.
3)
So,
when
TRAY
is
slanted
or
is
tilted
against
the
level
on
the
check
by
opening
F-Room
Door,
it
means
the
stop
by
F-Room
Door
OPEN
during
Horizontality
operation.
Therefore,
close
F-Room
Door
and
allow
to
return
to
the
Horizontality
after
water-supply.
30
seconds
after
F-Room
Door
is
closed,
check
the
Horizontality
and
if
not,
it
may
be
judged
to
have
something
wrong.
When
terminated
by
opening
of
F-Room
Door,
also
TEST
function
does
not
operate
and
operates
after
the
finish
of