Refer to the service manual in the GSPN(see the rear cover) for the more information.
AIR CONDITIONERCONTENTS
SYSTEM AIR CONDITIONER
Basic : CH140EAV/UH140GAV
Model
: CH070EAV1/CH090/105/140EAV
UH070EAV1/UH090/105/140EAV
Model Code : CH070EAV1/CH090/105/140EAV
UH070EAV1/UH090/105/140EAV


1. Precautions
2. Product Specifi cations
3. Disassembly and Reassembly
4. Troubleshooting
5. Exploded Views and Parts List
6. PCB Diagram and Parts List
7. Wiring Diagram
8. Schematic Diagram
9. Reference Sheet


Other manuals for Samsung UH070EAV1

Questions and Answers

  • V
    villanuevamatthewSep 23, 2025
    What to do if my Samsung UH070EAV1 Air Conditioner displays Indoor unit Eva In sensor (open/short)?
    • S
      Samuel ZamoraSep 23, 2025
      If your Samsung Air Conditioner displays an Indoor unit Eva In sensor (open/short), check the indoor unit drainage pipe sensor and the indoor PCB connector CN21 (white).
  • O
    ostanleyAug 23, 2025
    What to do if my Samsung Air Conditioner showing outdoor temperature sensor error?
    • J
      jonathan52Aug 25, 2025
      If your Samsung Air Conditioner displays an outdoor temperature sensor error, check the connection status of the sensor, its location, and the resistance values of the sensor.
  • M
    mprinceAug 25, 2025
    What to do if my Samsung UH070EAV1 displays a gas leakage error?
    • L
      Lisa MackAug 26, 2025
      If your Samsung Air Conditioner displays a gas leakage error, verify that the refrigerant is filled and check the indoor EVA sensor.
  • T
    Thomas LewisAug 27, 2025
    What to do if my Samsung Air Conditioner showing outdoor fan 1 error?
    • J
      Jessica TorresAug 27, 2025
      If your Samsung Air Conditioner displays an outdoor fan 1 error, check the input power connection status, the connection between the motor and PCB in the outdoor unit, and the fuse of the indoor/outdoor units.
  • B
    Brandon CabreraAug 27, 2025
    What to do if my Samsung UH070EAV1 showing outdoor fan 2 error?
    • G
      Gregory LozanoAug 27, 2025
      If your Samsung Air Conditioner displays an outdoor fan 2 error, check the connection status of input power, the connection status of the motor and outdoor PCB, and the fuse of the indoor/outdoor unit.
  • P
    paul01Sep 16, 2025
    What to do if my Samsung Air Conditioner displays a '[inverter] OTP error'?
    • T
      Terri RodriguezSep 16, 2025
      If your Samsung Air Conditioner displays an inverter OTP error, check if the PCB operates normally.
  • S
    simpsonthomasSep 13, 2025
    What to do if my Samsung UH070EAV1 displays a 'Dismount of indoor unit Eva In sensor' error?
    • K
      kennethcarrollSep 13, 2025
      If your Samsung Air Conditioner displays a 'Dismount of indoor unit Eva In sensor' error, check if the drainage pipe has been dismounted.
  • J
    Judy JordanSep 15, 2025
    What to do if my Samsung Air Conditioner displays a '[inverter] Current sensor error'?
    • U
      uchandlerSep 15, 2025
      If your Samsung Air Conditioner displays an inverter current sensor error, check if the PCB operates normally.
  • D
    Dana JohnsonSep 5, 2025
    What to do if my Samsung UH070EAV1 displays a '1min. Time out Comm. (Display Board : Onboard : Indoor ? Outdoor)' error?
    • M
      Michael WrightSep 5, 2025
      If your Samsung Air Conditioner displays a 1-minute time out communication error, check the indoor unit connection and the indoor unit option.
  • N
    Nathan OconnorSep 3, 2025
    What to do if my Samsung Air Conditioner displays a 'Non-connection error of indoor and outdoor Communication wire (connected to the power terminal)'?
    • M
      Michael WattsSep 3, 2025
      If your Samsung Air Conditioner displays a non-connection error of indoor and outdoor communication wire connected to the power terminal, check the status of the power connection and the connection status of the communication line.

Summary

Precautions

Installing the Air Conditioner

Guidelines for safe and proper installation of the air conditioner unit.

Power Supply and Circuit Breaker

Electrical safety requirements for power connection and circuit breaker usage.

During Operation

Safe operating procedures and precautions during normal use of the unit.

Disposing of the Unit

Environmental guidelines for proper disposal of the air conditioner.

Others

General safety notes, supervision for children, and measurement standards.

Product Specifications

Product Features

Key features and benefits of the air conditioner system, like cassette type and energy saving.

Detailed Product Specifications

Technical data including cooling/heating capacity, dimensions, power, and noise levels.

Comparative Product Specifications

Comparison of specifications between different development and comparative models.

Accessory and Option Specifications

List and details of accessories and optional components available for the unit.

Disassembly and Reassembly

Necessary Tools for Disassembly

Identifies essential tools like screwdrivers and spanners required for servicing.

Indoor Unit Disassembly

Step-by-step instructions for dismantling the indoor air conditioner unit.

Outdoor Unit Disassembly

Step-by-step instructions for dismantling the outdoor air conditioner unit.

Troubleshooting

Indoor Display Error Codes

Explains error codes indicated by the indoor unit's LED lamps and their meanings.

Wired Remote Controller Error Display

Lists error codes displayed on the wired remote controller and their explanations.

Outdoor LED Error Display

Details error codes indicated by outdoor unit LEDs (Yellow, Green, Red) and their causes.

Setting Option Setup Method

Guides for setting configuration options using the remote control for different model types.

Fault Diagnosis by Symptom

Provides troubleshooting procedures based on common symptoms like 'No Power' or 'Outdoor unit Power Supply error'.

PCB Inspection Method

Procedures for inspecting Printed Circuit Boards (PCBs) in both indoor and outdoor units.

Main Part Inspection Method

Methods for inspecting key components like sensors, fan motors, and solenoids for proper function.

Exploded Views and Parts List

Indoor Unit Exploded View and Parts

Visual breakdown of the indoor unit components with a corresponding parts list.

Panel Components Exploded View and Parts

Exploded view and parts list specifically for the panel components of the unit.

Outdoor Unit Exploded View and Parts

Visual breakdown of the outdoor unit components with a corresponding parts list.

Assy Control Out Exploded View and Parts

Exploded view and parts list for the Assy Control Out assembly.

PCB Diagram and Parts List

Block Diagram

Overview of the main PCB connections and functional blocks for indoor and outdoor units.

PCB Parts Lists

Detailed lists of components for various PCBs, including Indoor Main, Outdoor Main, EMI, and Inverter PCBs.

Wiring Diagram

Schematic Diagram

PCB Diagram Descriptions

Explanations of the different parts and sections within the PCB diagrams.

Outdoor Unit PCB Diagrams

Schematic diagrams for the main PCBs of the outdoor unit.

Indoor Unit Main PCB Schematic

Detailed schematic for the main PCB of the indoor unit.

Inverter PCB Schematic

Schematic diagram for the inverter PCB.

EMI PCB Schematics

Schematic diagrams for the EMI (Electromagnetic Interference) PCBs.

Reference Sheet

Refrigerating Cycle Diagram

Visual representation of the refrigerant flow and components in the air conditioning system.

Index of Model Name

Guide to understanding the model code structure and its corresponding product types and specifications.

Samsung UH070EAV1 Specifications

General IconGeneral
BrandSamsung
ModelUH070EAV1
CategoryAir Conditioner
LanguageEnglish

Related product manuals