EasyManua.ls Logo

Samsung UN KU650DF Series - Page 72

Samsung UN KU650DF Series
119 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SMPS POWER
Power TV On.1.
PS_ON . 2Vdc (when off) changes to 3.3Vdc (on)
May already be On if IoT USB is loaded or TV Smart Things Hub mode is active. -
if voltage error or no change.2.
Jog Function Control Test.
If OK replace Main Board.3.
All A13V supplies to full voltage level 12.7VDC.
If any wrong voltage, remove the SMPS connector to Main Board.4.
A13V again for 12.7VDC.
If OK replace Main Board.5.
If still wrong voltage replace SMPS.6.
OD (Over Voltage Detect) : 3.3Vdc (Operating Normal)
If 0V or changing, an SMPS or Panel error exists. Perform Backlight Test.7.
BLU_PWM 0V- Off to approx 1 – 3.3 V pending Backlight dim level
If missing/error replace Main Board.
Fuse
CNM803
1 Fail Count 7 A13V
2 ANA-DIM 8 POWER_ON/OFF
3 A13V 9 A13V
4 OD_ON/OFF 10 GND
5 A13V 11 GND
6 BLU_PWM 12 GND
CNL802
1 2+ 9 1+
2 NC 10 NC
3 NC 11 NC
4 2- 12 1-
5 NC 13 NC
6 NC 14 NC
7 NC 15 IF2
8 NC 16 IF1
CNL802
CNM803
4-3
4. Troubleshooting

Related product manuals