4-3. Factory Mode Adjustments
4-3-1. Detail Factory Option
NOTE
If you replace the main board with new one, please change the factory option as well.
The options you must change are "Type".
UN**JU6400FXZA
Inches 40" 48" 55"
PANEL
Vendor SEC SEC SEC/BOE
Code BN95-02280F BN95-02281F BN95-02121C
Spec. CY-GJ040HGLVDH CY-GJ048HGLVCV CY-GJ055HGLV7V
SMPS BOARD
Vendor HANSOE DYREL DYREL
Code BN96-35335A BN96-35336A BN96-35336A
Spec. L40S5_FHSV L55S5_FDYV L55S5_FDYV
MAIN BOARD
Chassis Ass'y BN91-14196F BN91-14196G BN91-14196H
PBA Ass'y BN94-09313P BN94-09313Q BN94-09313R
Byte Item
0 Factory Reset -
1 Type 40A6AU3VJ 48A6AU3VJ 55A6AU3VJ
2 Local set US US US
3 SW Model UJU6000 UJU6000 UJU6000
4 BOM Model 6400 6400 6400
5 Tuner S_TDA18275A S_TDA18275A S_TDA18275A
6 Ch table NONE NONE NONE