FUNCTION/IR Control
<DECO Lamp> <Function/IR>
LED Status / Function Switch
CN910 (FUNCTION/IR)
1 IR 3.3Vdc to 2.5Vdc (Effective DC) 2 GND
3 A3.3V_PW 4 AMP_SCL_I2C 3.3Vdc (effective DC)
5 AMP_SDA_I2C 3.3 Vdc (effective DC) 6 KEY_INPUT1 1.8dc to 0V with command
7 KEY_INPUT2 0V (no operation change) 8 LED_STB_OUT 1.7Vdc STBY
9 A3.3V_PW 3.3V to Deco Lamp 10 LED_CTRL to Deco Lamp 1Vdc (off) 0.5V (On)
CN910
TV in Standby 1.
LED Status
If 2. LED is OFF
LED 1.7Vdc (pin 8) and VCC for 3.3Vdc (pin 3)
If missing suspect Function Assy/Cable Assy/Main Assy.
If 3. LED is ON
Switch Operation activates on screen display.
<On Screen Selections with Function Control>
If missing: -
Key _Input1 Pin 6 change to 0V with a command.
If wrong voltage or no change: -
Switch for stuck or miss-operation.
Check 4. IR operation with Standard Remote command changes. (3.3V to 2.5V effective DC)
SDA5. , SCL for effective 3.3Vdc (after power on)
If missing suspect - Function Assy/Cable Assy/Main Assy.
4-3
4. Troubleshooting