Disassembly and Reassembly _ 21
Part Figure Description
Drain pump
6. Remove the holder by using a long nose
pliers.
Do not cut off the holder
7. Release the BAND RING (3EA) and
remove the HOSE (3EA).
8. Push the TUB inward slightly to remove the
PUMP.
Pump wire harness is connected to
main wire harness.
Check Points for Troubleshooting
1. Separate the Drain Filter and check if any alien substances are inside the pump (e.g.
coins, buttons .., etc.) Remove these if found.
2. Check if the wire driving the pump has come loose Take the relevant countermeasure if
necessary.
3. When water leaks, check the assembly status of the Clamp Hose, and Cap Drain Take
the relevant countermeasure if necessary.
Turn the lter counterclockwise to remove the remaining water.