28 _ Troubleshooting
Error Type
Drum
Fully
automatic
Causes Remarks
Error
mode
Old
error
mode
For USA
Water Leakage
Error
LE
LE1
11E
E9
LE LE
- Heaterengagementfault(outofplace)
- Theairhoseisoutofplaceandwaterleakage
occursduringthespincycle.
- Thetubebackneartheboltxingpartisbroken.
- Waterleakageoccursatthefrontwithfoaming
becauseoftoomuchdetergent
- Waterleakageoccursbecausetheconnecting
hosetothedetergentdrawerisconnected
incorrectly.
- Thedrainpumpltercoverisengagedincorrectly.
- Waterleakageoccursatthedrainhose.
- Theductcondensingholdingscrewsareworn.
- Thenozzle-diaphragmisengagedintheopposite
directionortherubberpackagingisomitted.
- Waterleakageoccursbecausethescrewsthat
holdthetubbackandfrontinplacearefastened
incorrectly.
- Theleakagesensorisfaulty.
Overow Error
OE
OF
OE
OF
E3
OE -
- Waterissuppliedcontinuallybecausethewater
leveldetectiondoesnotwork.
- Becausethedrainhoseiscloggedandthere
isaninjectionerror(atanarrowsection),the
waterleveldetectiondoesnotworkandwateris
suppliedcontinually.
- Waterissuppliedcontinuallybecauseoffreezing
orbecausethereisforeignmaterialinthewater
supplyvalve.
- Thiserrormayoccurwhenthewaterlevelsensor
isdegraded.
ForUSA
products,this
error occurs
becausethe
waterlevel
sensorterminal
isoutofplace.
Temperature
Sensor Error
tE1
tE1
6E
tE -
- Thewashingheaterinthetubhasanerror.
(Contacterror,temperaturesensorfault)
- Theconnectorisconnectedincorrectlyoris
disconnected.
- Ifthewaterlevelsensoroperateswithoutwater
becausethewaterisfrozenorforanyother
reasonandthetemperaturesensorengagedat
thebottomtopreventoverheatingofthewashing,
thenthesensordetectsatemperatureof100-
150°Cthenthewashingmachineturnstheinput
poweroff.
Heater sensor
fault
:Whenthe
connector is
connected
incorrectlyor
hasawire
disconnected
or contact error
tE2 tE2 - -
- Thetemperaturesensorfortheductassyfan
housingisfaulty.
(Asensorfaultsuchasaninternalshort-circuitor
wiredisconnection)
- Theconnectorisoutofplaceorhasacontact
error.
Duct
condensing
temperature
sensorfault(for
modelsbefore
thesilvernano
functionwas
applied)
tE3 tE3 - -
- Thisoccurswhentheductcondensing
temperature sensor is open.
- Thisoccurswhentheductcondensing
temperaturesensorhasawiredisconnectedoris
short-circuited.
- Theconnectorisoutofplaceorhasacontact
error.
Dryheater
temperature
sensorfault(for
modelsbefore
thesilvernano
functionwas
applied)
Unbalance
Error
UE
UE
E4
dc UE
- Aslaundrycausesthiserror,checkthelaundry.
- Findthereasonfortheunbalanceandsolveitas
directedintheusermanual.