1st Edition of TEMI2000_Series IM : Dec. 15. 2008 Page 14 / 58
5.7 WRD Command
WRD Command is used to write data in arbitrary single D-Register.
Request Message Frame
Bytes 1 2 3 1 2 1 4 1 4
Frame STX Address WRD ,
Count
Number
, D-Reg.- 1 , Data - 1
1 1 4 1 4 2 1 1
, , D-Reg. - n , Data - n SUM CR LF
Response Message Frame
Bytes 1 2 3 1 2 2 1 1
Frame STX Address WRD , OK SUM CR LF
Count Number : 1 ~ 64
Data : Hexa-decimal 16bit string 4 character with no decimal point
Example
To write 50.0 ℃ into the D0102(TEMP.SP) and 0.5 ℃ into the D0106(TEMP.SLOPE) on FIX mode operation.
- Setting TEMP.SP : 50.0 ℃ → Remove decimal point (500) → Hexadecimalize (0x01F4)
- Setting TEMP.SLOPE : 0.5 ℃ → Remove decimal point (5) → Hexadecimalize (0x0005)
- Request : [stx]01WRD,02,0102,01F4,0106,0005[cr][lf]
- Request(with CheckSum) : [stx]01WRD,02,0102,01F4,0106,0005B6[cr][lf]