STEP
SEQUENCE
RESULT
b
Resistance
OK
Replace control
circuit board.
(4) PROBLEM
Low microwave power
output.
a
Normal control
circuit board
Replace Blower
motor
0
Resistance
incorrect
274
Normal
Resistance
Replace thermal protector
for magnetron or thermal
protector for cavity.
0
0
Defective H.V capacitor,
H.V diode or H.V. fuse.
Replace HV
capacitor, H.V
diode or H.V.
fuse.
Replace HV
Magnetron.
Runs
Runs
Runs
Runs
Runs
Runs
0
0
Resistance
Incorrect
-12-
Normal Blower
Motor
Measure resistance
of blower motor
(Approx 300 ohms)
No
Operation
Normal thermal protector for
magnetron or thermal
protector for cavity.
Normal
Operation
Temporarily
short across
terminals of
thermal protector
for magnetron
or thermal
protector for
cavity by using
jumper lead.
No
Operation
Normal
Operation
PROBLEM
3-b
Check operation
of blower motor
when START key
is touched.
Check resistance of
each winding after
removing lead wires.
(See page 6 )
Normal HV Transformer
Check H.V capacitor , H.V.
diode or H.V fuse with an
ohm-meter after removing
the lead wires.( See page 6 )
Normal H.V capacitor,
H.V diode or H.V. fuse.
Replace HV
Transformer
Normal
Magnetron
Normal H.V
capacitor ,
diode or fuse.