CD PLAYER ADJUSTMENTS
.-
.,
.:.
.:
J
., .,,
.. .,
Adjustment
Measuring
Short-
Input output
Item
circuit
instrument
connection
connection
location
(a) PLLVCO
Frequency counter SHORT 1
TP 5 (PLL)
free-run
TP 4 (GND)
Adjust-
ment
location
--- .
A
Adjustment value
4.300 MHz -5.000 MHz
Waveform symmetry
A =B 1.5 Vp-p
Check be sure that the
“eye” pattern is at the
center of the waveform
and that the diamond
ShaDe is clearlv defined
SVR302
(b) Tracking
Oscilloscope
L.P.F. SHORT 1
TPI:TE
balance
TP 2: VC2.5V
(c) Checking
the “eye”
Oscilloscope
TP3:RF
pattern
TP 2: VC2.5V
d.
ADJUSTMENTS
t
(a
(1)
(2)
(3)
) PLL VCO free-run adjustment
Test disc removed from the unit.
TP5 ~
Short-circuit points 1 on the printed-circuit board.
Connect a frequency counter to TP 5 ( PLL ) and
TP 4 ( GND ).
TP4 ~
Switch ON the DC power ( 12.O,V )
. .
.-
FREQUENCY
COUNTER
(4)
(See component locations diagram at page 5)
Check the reading of the frequency counter
!.
.-
is 4.300 MHz -5.000 MHz. ‘“
.
-,
~:
Cancel the short-circuiting of short-circuit point 1 ~ ‘~“~”-
on the printed-circuit board. -
..’.
... ,”,
.
,1,
~~
L.P. F.
,
(5)
(6)
- ..
( b ) Tracking balance adjustment TP1 <~~~
+
I
(1)
(2)
(3)
(4)
(5)
(6)
Short-circuit points 1 on the printed-circuit ward..,,. ;. . .“ . .
Connect an oscilloscope to 1P 1 (TE) and TP 2 (VC 2.5V).~Y ;~-:--,y.-, IN
-
‘-’”-- 3 ;
Switch ON the DC power. ‘------- .. ...... .. -—.---..-–.-.--12- . ~p ~.-... -
Set the test disc.
-1
PLAY switch push ON.
OSCILLOSCOPE
Cancel the short-circuiting of short-circuit point 1
on the printed-circuit board.
Adjust SVR302 so that the oscilloscope’s waveform is .
symmetrical, as shown in the illustration.
Switch OFF the DC power.
Ov
1.5vp-p
1
VIDIV
h-g
(7)
(8)
(c
The adjustments (a) - (b) complete the adjustments of
the CD player.
Next, check the eye pattern waveform.
‘p’
1 OsclLLOscOpE
) Checking the eye pattern
+~
Switch ON the DC power.
Connect an oscilloscope to TP 3 ( RF) and
TP 2 (VC 2.5V ).
Load the test disc.
PLAY switch push ON.
Check to be sure that the eye pattern is at the center
of waveform and that the diamond shape is clearly defined.
Press the STOP button.
Switch OFF the DC power.
(1)
(2)
I
(3)
(4)
(5)
0
(6)
(7)
H-ttni-ti-n AA/