EasyManua.ls Logo

Sanyo PLUS T35 - Display Unit Terminals and Signal Level; Display Unit Terminal Functions; Signal Level Display Operation

Sanyo PLUS T35
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1F-AM
(pin
No.
8).
!t
can
determine
the
setting
of
the
intermediate
frequency
of
FM,
and
is
controlled
by
0004,
0005,
and
0007.
H
level:
+10.7
MHz.
IF-AM1
(pin
No.
11),
IF-AM2
(pin
No.
9).
These
terminals
together
with
FM/AM
terminal,
can
determine
the
intermediate
frequency
of
MW
(AM),
and
are
con-
trolled
by
0004,
Q005,
and
0007.
In
all
three
terminals,
L
level:
+445
MHz.
FM-Fine
(pin
No.
13).
This
terminal
is
an
input
for
fine
adjustment
to
correct
the
deviation
of
intermediate
frequency
of
FM,
and
feeds
divided
voltage
of
semi-
variable
resistor
R039.
AM-Fine
(pin
No.
14)
This
terminal
is
an
input
for
fine
adjustment
to
correct
the
deviation
of
intermediate
fre-
quency
of
MW
(AM),
and
feeds
divided
voltage
of
semi-
variable
resistor
RO40.
Vref
(pin
No.
10).
This
terminal
is
at
the
reference
voltage,
and
is
controlled
by
0004,
Q005,
and
Q007.
TRC/CLK
(pin
No.
15),
SET
(pin
No.
16),
DEMAND
(pin
No.
17),
12H/24H
(pin
No.
18).
These
terminals
are
for
controlling
the
clock,
which
are
not,
however,
used
in
this
model,
and,
hence,
set
at
H
level.
0
(pin
No.
5).
This
terminal
is
to
light
the
lowest
digit
of
display
in
the
case
of
FM
band.
It
is
held
at
H
level.
When
voltage
is
applied
to
segments
a,
c,
d,
f,
and
g
of
the
lowest
digit
and
to
the
plate
terminal,
the
numeral
“6”
will
be
illuminated
(when
pin
No.
4
is
0
V).
Q203__LA1231
FM
1F
-
SYSTEM
Q108
LA1240
AM
TUNER-SYSTEM
R234
(tees
Lies
e@
5
(pin
No.
4).
This
terminal
is
intended
to
change
over
the
display
of
the
lowest
digit
in
FM
band
between
0
and
5.
,
L
fevel:
H
level:
State
of
0
(pin
No.
5)
held
“5”
lighted.
0008
turned
ON,
voltage
not
impressed
to
segment
g,
instead
impressed
to
plate
terminals
of
segment
b,
and
e
“0”
lighted.
Signal
level
display
The
display
of
signal
level
meter
(electric
field
intensity
display)
is
formed
in
the
upper
part
of
the
dial
case
with
two
LEDs
in
five
stages
(5
segments).
The
principle
of
signal
level
meter
display
is
to
pick
up
IF
signal
of
FM
or
MW
(AM),
and
to
present
a
display
through
the
segment
driver
after
A-D
conversion
in
5
stages.
The
FM
IF
signal
is
picked
up
from
the
output
of
signal
meter
drive
(pin
No.
13)
of
Q203
(FM
IF
system).
The
MW
(AM)
IF
signal
is
picked
up
from
pin
No.
15
of
Q108
(AM
tuner
system).
The
signal
thus
taken
out
is
fed
into
IN3
(pin
No.
3,
IN}
(pin
No.
2)
of
0204
(5-bit
level
meter)
through
signal
adjusting
semivariable
resistors
R228,
R234.
The
input
signal
is
amplified
by
operational
amplifiers
A1,
A2
in
Q204,
and
is
compared
in
operational
amplifiers
C1
through
C5,
to
be
divided
into
signals
in
5
stages.
The
reference
voltage
to
compare
with
is
divided
by
R1
through
R5
to
be
generated.
When
an
input
higher
than
the
com-
parative
reference
voltage
is
fed,
the
output
becomes
H
level,
thereby
lighting
up
the
LED.
Q204
LB1416
SBIT
SIGNAL
LEVEL
METER
a
pei
a
us
@l
LED
7
SLLO
002GR
LED
8
SLLD
003GR