Single-room operation
Indoor unit
Indoor Unit Capacity (kW)
Conbination
Room A Room B Room C Total Performance Power Input (W) Current (A)
Min. - Max. Min. - Max.
2.8 Heating 4.0 4.0 1,320 6.2
0.9 - 5.4 590 - 1,660
Cooling 2.8 2.8 960 4.5
0.7 - 3.2 330 - 1,080
3.6 Heating 4.8 4.8 1,510 7.1
0.9 - 6.3 590 - 1,870
Cooling 3.6 3.6 1,190 5.6
0.8 - 3.6 360 - 1,190
5.0 Heating 7.1 7.1 1,980 9.3
1.2 - 7.8 690 - 2,130
Cooling 5.0 5.0 1,660 7.9
1.1 - 5.8 450 - 1,900
Two-room operation
Indoor unit
Indoor Unit Capacity (kW)
Conbination
Room A Room B Room C Total Performance Power Input (W) Current (A)
Min. - Max. Min. - Max.
2.8+2.8 Heating 3.65 3.65 7.3 2,110 9.9
1.7 - 8.4 780 - 2,370
Cooling 2.80 2.80 5.6 1,790 8.5
1.4 - 6.5 540 - 2,060
2.8+3.6 Heating 3.30 4.00 7.3 2,110 9.9
1.7 - 8.4 780 - 2,370
Cooling 2.45 3.15 5.6 1,790 8.5
1.4 - 6.5 540 - 2,060
3.6+3.6 Heating 3.65 3.65 7.3 2,110 9.9
1.7 - 8.4 780 - 2,370
Cooling 2.80 2.80 5.6 1,790 8.5
1.4 - 6.5 540 - 2,060
2.8+5.0 Heating 2.65 4.65 7.3 2,170 10.2
1.6 - 9.0 780 - 2,390
Cooling 2.00 3.60 5.6 2,030 9.6
1.2 - 7.0 480 - 2,270
3.6+5.0 Heating 2.95 4.35 7.3 2,170 10.2
1.6 - 9.0 780 - 2,390
Cooling 2.35 3.25 5.6 2,030 9.6
1.2 - 7.0 480 - 2,270
Outdoor Unit SAPCMRV1923GJH
2.8: SAP-#MRV93GJH
3.6: SAP-#MRV123GJH
5.0: SAP-#MRV183GJH
NOTE
2-Room Outdoor Unit Combination Table
46
Single-room operation
2-room operation
Indoor Unit
Combination
Indoor Unit
Combination