EasyManua.ls Logo

Sanyo SAP-CMRV2433GJH - Page 51

Sanyo SAP-CMRV2433GJH
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Three-room operatio
Indoor unit
Indoor Unit Capacity (kW)
Conbination
Room A Room B Room C Total Performance Power Input (W) Current (A)
Min. - Max. Min. - Max.
2.8+2.8+2.8 Heating 2.86 2.86 2.86 8.6 2,260 10.6
1.7 - 9.0 820 - 2,350
Cooling 2.26 2.26 2.26 6.8 2,040 9.7
1.4 - 8.1 620 - 2,380
2.8+2.8+3.6 Heating 2.70 2.70 3.20 8.6 2,260 10.6
1.7 - 9.0 820 - 2,350
Cooling 2.07 2.07 2.65 6.8 2,040 9.7
1.4 - 8.1 620 - 2,380
2.8+2.8+5.0 Heating 2.30 2.30 4.00 8.6 2,260 10.6
1.7 - 9.0 820 - 2,350
Cooling 1.80 1.80 3.20 6.8 2,040 9.7
1.4 - 8.1 620 - 2,380
2.8+3.6+3.6 Heating 2.50 3.05 3.05 8.6 2,260 10.6
1.7 - 9.0 820 - 2,350
Cooling 1.90 2.45 2.45 6.8 2,040 9.7
1.4 - 8.1 620 - 2,380
3.6+3.6+3.6 Heating 2.86 2.86 2.86 8.6 2,260 10.6
1.7 - 9.0 820 - 2,350
Cooling 2.26 2.26 2.26 6.8 2,040 9.7
1.4 - 8.1 620 - 2,380
2.8+3.6+5.0 Heating 2.15 2.60 3.85 8.6 2,260 10.6
1.7 - 9.0 820 - 2,350
Cooling 1.65 2.15 3.00 6.8 2,040 9.7
1.4 - 8.1 620 - 2,380
Outdoor Unit SAPCMRV3143GJH
2.8: SAP-#MRV93GJH
3.6: SAP-#MRV123GJH
5.0: SAP-#MRV183GJH
NOTE
48
3-room operation
Indoor Unit
Combination

Related product manuals