1. Specifications
1
2
3
4
5
I - 121
SM830080
1-11 Installation Instructions
Electrical Characteristics
Indoor Unit : SPW-DR363GH56 Outdoor Unit : SPW-CR363GHL8
SPW-CR363GL8
● Cooling
Indoor Unit Outdoor Unit
Complete Unit
Fan Motor Fan Motor Compressor
Performance at 220 - 240 V / 1 phase / 50 Hz 380 - 415 V / 3 phase / 50 Hz
Rating conditions
A 2.46 / 2.47 1.24 / 1.31 6.35 / 6.39 7.43 / 7.45
kW 520 / 570 0.26 / 0.29 3.46 / 3.51 4.24 / 4.37
Full load conditions
A 2.46 / 2.47 1.24 / 1.31 7.2 / 7.24 8.29 / 8.31
kW 520 / 570 0.26 / 0.29 3.98 / 4.02 4.76 / 4.88
Starting amperes A 4 / 4 3 / 3 42 / 45 49 / 52
● Heating (Heat pump only)
Indoor Unit Outdoor Unit
Complete Unit
Fan Motor Fan Motor Compressor
Performance at 220 - 240 V / 1 phase / 50 Hz 380 - 415 V / 3 phase / 50 Hz
Rating conditions
A 2.46 / 2.47 1.24 / 1.31 7 / 7.04 8.09 / 8.1
kW 520 / 570 0.26 / 0.29 3.86 / 3.88 4.64 / 4.74
Full load conditions
A 2.46 / 2.47 1.24 / 1.31 7.4 / 7.44 8.49 / 8.51
kW 520 / 570 0.26 / 0.29 4.08 / 7.12 4.86 / 4.98
Starting amperes A 4 / 4 3 / 3 42 / 45 49 / 52
Cooling:
Rating Conditions : Indoor Air Temperature 27°C DB / 19°C WB
Outdoor Air Temperature 35°C DB
Full Load Conditions : Indoor Air Temperature 35°C DB / 23°C WB
Outdoor Air Temperature 43°C DB
Heating:
Rating Conditions : Indoor Air Temperature 20°C DB
Outdoor Air Temperature 7°C DB / 6°C WB
Full Load Conditions : Indoor Air Temperature 24°C DB
Outdoor Air Temperature 21°C DB / 15.5°C WB