4. Service procedures
1
12
3
4
5
IV - 30
SM830080
e Set the required new indoor unit’s No. by pressing the , ( ) button.
f Press the SET button.
UNIT No, SET DATA (0008) and
SETTING
changes from flashing to ON state.
g If you made a mistake, press the CL button.
h Finally, press the TEST / CHK button.
i If you want to change the indoor unit address of the other R.C. No., follow the step a
to h in the same way.
*
In this case, UNIT No. 3 6 (current)
3 8 (NEW : after pressing the
TEST / CHK button)
SET CL
MODE
FAN SPEED
ON
OFF
SET TEMP.
UNIT
FLAP
AIR FLOW
R.C. No.
SET
No.CODE
TIMER SET
DATA
SETTING
TEST / CHK
0364_M_I
Ex: UNIT No. 3-6: currently registered indoor unit address
Required new indoor No.8: SET DATA