Horizontal size scale
*
5. Vertical Size Adjustment
Measuring Point I
Measuring Equipment
Condition
I
Viewfinder
Playback
~
(WR5-5CSP). For operation check,
ADJ. Location
ADJ. / Check Value
VR972
Preparation:
● POWER switch: “ON”
● Power mode button: “PLAYER”
● Short pin @ and pin @ of J1OO5.
Adjustment:
1.
Turn and adjust VR972 within 87.5 to 92.5 on the vertical
size scale of the monoscope signal.
6. Brightness Adjustment
Measuring Point
Measuring Equipment
Condition
Viewfinder
Playback
Input Signal / Alignment Tape
(WR5-5CSP): For operation check,
monoscope portion
ADJ. Location
ADJ. / Check Value
VR975
7. Focus Adjustment
Meaauring Point
Measuring Equipment
Condition
—
Viewfinder
Playback
~
(WR5-5CSP). For operation check,
ADJ. Location
ADJ. / Check Value
VR974
Preparation:
● POWER switch: “ON”
● Power mode button: “PIAYER”
● Short pin @ and pin @ of J1OO5.
Adjustment:
1.
Adjust VR974 so as to optimize resolution of the mono-
scope pattern.
Preparation:
● POWER switch: “ON”
● Power mode button: “PLAYER”
Adjustment:
1. Adjust to adequate brightness with VR975.
–22–