54
Example
Determine the weight of a sample in extremely unstable ambient conditions from
the average result of 5 subweighing operations. Enter the number of subweighs
while in the weighing mode
Configuration (changes in the factory settings required for this example):
Menu path: Application > Averaging (2 1 12)
Step Key (or instruction) Display/Output
1. Turn on the scale e
2. Zero the scale, if necessary ( 0.000 kg
10
3. Set the number of subweighs w ref 20 (briefly)
for averaging (in this w ref 50 (briefly)
example: 5 subweighs) w ref100 (briefly)
w ref1 (briefly)
w ref 2 (briefly)
w ref 5 (briefly)
0.000 kg
5
4. Place sample on the scale + 8888
5
(weight readout fluctuates;
in this case, around 275 g)
5. Start measurement v 8888
5 . . . 1
If the printout is configured to 0.275 kg
5
to include data ID codes, the
data is printed as shown here Res + 0.275 kg
6. Unload the scale 0.275 kg
5
7. Repeat the procedure starting
from Step 4, if desired.