Photoelectric Beam Detector
SASO-PB D
Installation Instructions
Please note : This sensor is designed to detect intrusion and to initiate an alarm,
it is not a burglar-preventing device. Maker is not responsible for damage, ,injury
or losses caused by accident, theft, natural disasters, abuse, misuse, abnormal usage,
faulty installation or improper maintenance.
1. Description
Response time
adjustment
Terminals
Good LED
Tamper
Wiring Hole
Power LED
Tamper
Alarm LED
Lens
Monitor jack
Vertical
Adjustment screw
View finder
Cover
Transmitter
Receiver Plate
2. Cautions on Installation
3. Installation
3-1. Wall mount
Avoid direct
contact of sun,
auto-mobile head-
lights etc. to
transmitter or
receiver
Do not install the
unit on unsteady
surfaces.
Do not install in a
site where beams
may be interrupted
by trees or plants.
Do not install in
places where
units may be
splashed
continuously by
dirty water or
direct sea spray.
Remove cover from unit
and slide the mounting
plate to detach it.
Break grommet on mounting plate
and pull wire through it. Secure
the plate with 4mm screws.
When exposed wired, break knock-
outs on the rear of unit, pull wire
through as the figure and attach it to
the mounting plate.
After wiring is completed,
adjust alignment, check
operation and attach cover.
3-2. Pole mount (Pole size : Φ38 ~ Φ44mm)
Remove cover from unit and slide the mounting plate to detach it.
Attach pole brackets to pole and secure to mounting plate with screws.
Attach sensor body.
Pull through wire.
Connect terminals.
After wiring is completed, adjust alignment, check operation and attach cover.
4 Response time
1. Run at full speed
(6.9m/s) - 50msec.
2. Walk with quick steps
(1.2m/s) - 200msec.
3. Walking (0.7m/s)
- 300msec.
4. Walk with slow steps
(0.5m/s) - 500msec.
5~6. Go over a fence(0.3m/s)
- 700msec.
4
.
Response
time
Response time
adjustment
50ms
700ms
5. Channel setting
Purpose of this function is to prevent cross-talk or bypass of
beams which may occur in line protection or 2-stacked protection.
1ch 2ch 3ch 4ch
Question and Answer IconNeed help?

Do you have a question about the Saso SASO-PB D and is the answer not in the manual?

Summary

Product Description

Installation Cautions

Environmental Installation Precautions

Avoid direct sunlight, unsteady surfaces, obstructions by trees, and proximity to water or sea spray.

Installation Procedures

Wall Mount Installation

Steps for detaching the mounting plate, preparing it, pulling wires, and securing the unit.

Pole Mount Installation

Steps for attaching pole brackets, securing the sensor body, pulling wires, and connecting terminals.

Response Time Settings

Channel Setting

Wiring Guide

Adjustment and Monitoring

Troubleshooting

Specifications

Saso SASO-PB D Specifications

General IconGeneral
BrandSaso
ModelSASO-PB D
CategorySecurity Sensors
LanguageEnglish