16
Cooling System
CAUTION: To prevent compressor and/or property damage, if the
outdoor temperature is below 50ºF (10ºC), DO NOT operate the
cooling system.
1. Move the SYSTEM switch to the COOL position.
2. When the (FA)st cooling cycle rate is selected in the configuration
menu, (see configuration menu item 2), the thermostat will call for
cooling at 0.5ºF (0.5ºC) above set-point, and turn off at set point. When
the (SL)ow cool cycle rate is selected, the thermostat will call for
cooling at 1.5ºF (1.5ºC) above set-point, and turn off at set-point. When
the thermostat calls for cooling, the display will show COOL On. If the
COOL On display is flashing, the compressor lockout feature is
operating. (Note: See Configuration menu item 8). If all functions