DS 3.401 2 - 10 11/99
SPECIFICATIONS
ACCESSORIES
Auxiliary Switches: Kit 831-1-211 available for internal mounting.
Two voltage-free change-over switches rated 5A, 250V. Adjustable,
one from position 0 to 5, the other from position 5 to 10 (see Table on
page 2 for usage).
Spindle Adaptor: Kit 862-1-402, ¼" 32-UNEF female x
3
/
8
" 24-UNF
male. One supplied with each actuator, except ALX 1251 and
ALE 1352, for which it is not required.
TYPES ALM 1601 ALX 1201 ALX 1251 ALE 1302 ALE 1327 ALE 1352 ALE 1376
STROKE Standard Standard Short Standard Standard Short Standard
POWER SUPPLY: 220 to 240V +10% to -15%,
50/60 Hz
24V ±10%, 50/60 Hz
supplied by a transformer
conforming to EN 60742
24V ±10%, 50/60 Hz supplied by a
transformer conforming to EN 60742
POWER
CONSUMPTION:
LIMIT & TRANSFER
SWITCH RATING:
4.5 VA
5A
3.5 VA
0.75A
3.5 VA
0.75A
9.5 VA
12 VA
9.5 VA
12 VA
RUNNING SPEED:
1.8 s/mm (46 s/in)
2.5 s/mm (64 s/in)
5.0 s/mm (127 s/in)
8.5 s/mm (216 s/in)
MAXIMUM STROKE:
16 mm (5/8")
38mm (1½")
THRUST
311N
538N
AUXILIARY
SWITCHES
Two 5A, 250V
Adjustable
Use kit 831-1-211
Two 5A,
250V
Adjustable
Use kit
831-1-211
One 5A,
250V
Fixed
Built-in
Two 5A, 250V
Adjustable
Use kit 831-1-211
One 5A,
250V
Fixed
Built-in
Two 5A, 250V
Adjustable
Use kit
831-1-211
INPUT: CONTROL
SIGNAL (for
modulation)
Pulsed - Mains
(220 to 240Vac) Voltage
Pulsed - 24V 0-10Vdc
APPLICATION Two-position control from
thermostat, time switch or other
switching device having (220/
240Vac) mains rated
changeover contacts.
Modulating control from any
controller having a 3-wire
mains output (220 to 240Vac).
Modulating control from any
controller having a pulsed
24V output.
Modulating control from any controller providing a 0-10Vdc
positioning signal.
Start and Span adjustments, also DA/RA switch included.
Refer to 'Operation'.
ASSOCIATED
CONTROLLERS:
CMC, CSMC MMC, CXR, CXT, IAC, URC MMC, KMC, DRTE, DDTE, DSTE, DWTE,
CZT, BAS, IAC
MMC, KMC,
BAS, IAC
CSC CSC
ASSOCIATED
VALVES:
2 - Port: See DS 4.110
VSFupto25mm
VZ up to 2"
VSFupto25mm
VZ up to 2"
VSF up to 25mm
VZ up to 2"
VSF 32 to
50mm
VZF 65 to
150mm
VSF 32mm to 50mm
VZF65to150mm
VSF 32 to
50mm
VZF 65 to
150mm
3 - Port: See DS 4.610 MJFupto50mm
MZ up to 2"
MZF up to 150mm
MJFupto25mm
MZ up to 2"
MJFupto25mm
MZ up to 2"
MJF 32 to
50mm
MZF 65 to
150mm
MJF32to50mm
MZF65to150mm
MJF 32 to
50mm
MZF 65 to
150mm
Action: Reversing - modulating
Stroke Time: See table above
Protection Class: IP 54
Mounting Attitude: See 'Installation Instructions' on page 5
Ambient Temperature Limits:
Operating: -20 to 50°C
Storage: -40 to 70°C
Max. Ambient Humidity: Operation & Storage: 95% rh non-condensing
Manual Operator and Override: Standard feature with all types