Maintenance
6-8
CAUTION: Be very careful when cleaning the charge electrode.
Serious misalignment or damage may occur if excessive force is
used during cleaning.
6. Ensure the printhead is pointed down into the grounded service
tray. Flush away contaminants using the recommended SATURN
cleaning solution or make-up fluid. (Refer to Figure 6-4.)
H.V. Deflection Electrode
Gutter
Nozzle Plate
Screw for Printhead Cover
Charge Electrode
Cleaning
Range
Do not clean this area
with Cleanings.
Use wet paper with
cleanings to clean this
area.
Nozzle
Figure 6-4. Cleaning the Printhead
7. Dry the printhead completely, using tool in the accessories bag.
8. Remove the printhead from the service tray.
9. Clean the printhead cover if it is dirty, and then replace the
printhead into the cover.
10. Dispose of the cleaning solution in the service tray (or other waste
container used) properly.
Warning:
Do not pour cleaning solution into sinks, sewers, or
drains. Comply with all appropriate regulations when disposing of
printer fluids. Consult the appropriate regulatory agency for further
information.
Caution
: In some instances as abnormal shutting down, you
may have to carefully reclean the “Nozzle Plate” and “Charge
Electrode” , then dry it before use.