5. ELECTRONIC CONTROLLER INSTRUCTION
5-1-1.
DIXELL XR60C PARAMETER FOR FREEZER
SMG12F
NO.
Label
Name
Range
Hidden
Par.
Default
/
1
Set
Set point
LS-US
-5/23
-22
-7
2
Hy
Differential
0.1-25.5/1-255
2/35.6
2
4
3
Ls
Minimum set
point
-50-SET/-58-SET
Yes
-50/-58
-24
-11
4
Us
Maximum set
point
SET-110/SET-230
Yes
110/23
0
-18
-1
5
Ot
Thermostat
probe
calibration
-12-12/-120-120
0/32
2
-1
6
P2P
Evaporator
probe
presence
n=not pres. ;y=pres.
Y
Y
Y
7
OE
Evaporator
probe
calibration
-12-12/-120-120
Yes
0/32
0
0
8
Ods
Outputs
delay at start
up
0-255min
Yes
0
2
2
9
AC
Anti-short
cycle delay
0-50min
1
2
2
10
CCt
Continuous
cycle
duration
0.0-24.0h
Yes
0.0
0.0
0.0
11
COn
Compressor
ON time with
faulty probe
0-255min
Yes
15
10
10
12
COF
Compressor
OFF time
with faulty
probe
0-255min
Yes
30
10
10
13
CF
Temperature
measuremen
t unit
/
Yes
/
14
rES
Resolution
in=integer; dE = dec .point
DE
DE
DE
15
Lod
Probe
displayed
P1;P2
Yes
P1
P1
P1
16
tdF
Defrost type
EL= el.heater; dE= dec. point
EL
EL
EL

Related product manuals