Materials : Sensor Body : Acetal Copolymer, TICONA M90
Turbine : Acetal Copolymer, TICONA M90
Stick of Turbine : #304 Stainless Steel
O-Ring : EPDM Rubber
Housing : ABS resin
5.0 Operation Guide
5.1 Install Batteries
Slide off the cover case of the battery room, and put into 2 AAA batteries. Then slide the cover case
back.
5.2 Connecting Fitting
The specification of the DigiFlow 8000T connectors is 3/8” MNPT female. You could use any 3/8”
MNPT male connectors.
5.3 Setting Filter Capacity and Elapse Time Monitor
Keep pressing DISPLAY button, then press RESET button and release both of the buttons. The
DigiFlow 8000T will go into setting procedure. The digit will blink to notice you that the setting
procedure is on.
5.4 Setting Filter Capacity
Press
DISPLAY button to choose the capacity value. The sequence is OFF - 0 – 100 – 200 –
300 …… 19800 – 19900 – OFF – 0 –100 (gallon model) and OFF - 0 –500 – 1000 --- 99500 –
OFF – 0 – 500 (Liter model). Then press RESET button to save the filter capacity value. Then go
into elapse time value setting.
5.5 Setting Filter Elapse Time
Press DISPLAY button to choose the elapse time value. The sequence is OFF - 0 – 30 – 60 –
90 ….…… 690 – 720 – OFF – 0 –30. Then press RESET to save the Timing. The setting
procedure is completed.
Right to Left or Left to Right
Flow Rate : Max.4.10 gpm, 15.51 lpm
Min. 0.45 gpm, 1.70 lpm
4.0 General :
Temperature : 0 to 80
(32 to 176 )
Pressure : Max. 5.5 bar (80 psi)
Weight : 140 g (5.38 oz)
Accuracy : +/- 5%
Connection : 3/8 inch NPT Female