Drain Line Connecon
The unit should higher than, and not more than 6 metres from the drain. Use an appropriate
adapter ng to connect 1/2” (12.4mm) plasc tubing to the drain (discharge) hose
connecon of the control valve.
The drain (discharge) hose may be elevated up to 1.8 meters providing the run does not
exceed 4.6 meters and water pressure at the soener is not less than 2.76 bar.
Where the drain (discharge) hose is elevated but empes into a drain below the level of the
control valve, form an 18cm loop at the far end of the line so that the boom of the loop is
level with the drain hose connecon. This will provide an adequate siphon tap.
Where the drain (discharge) empes into an overhead sewer line, a sink-type U-bend trap
must be used.
Secure the end of the drain (discharge) hose to prevent it from moving.
Drinking Water
When ng your Water Soener, allowance should be made for at least one drinking water
tap that is not fed by the Water Soener. Where praccal this should be at the kitchen sink
but a Ulity Room or other suitable alternave will suce.
It is recommended that people on a low sodium diet should not drink arcially soened
water. Water used for mixing infant powder for babies must only be taken from unsoened
water as soened water contains an increased level of sodium which will not be accounted
for in the infant formula.
Brine Line Connecons
Check the connecons taking care not to over-ghten. Be sure that the regeneraon line is
secure and free from air leaks.
Electrical Connecon
For added safety the Scalemaster 100/200 series control operates on low voltage via a
plug in transformer. Use only the transformer supplied with the soener.
ANY ELECTRICAL WORK REQUIRED TO INSTALL A MAINS POWER SUPPLY FOR
THE WATER SOFTENER SHOULD ONLY BE CARRIED OUT BY A FULLY
QUALIFIED ELECTRICIAN.