EasyManua.ls Logo

Scalemaster Softline 100 - Page 5

Default Icon
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
Drain Line Connecon
The unit should higher than, and not more than 6 metres from the drain. Use an appropriate
adapter ng to connect 1/2” (12.4mm) plasc tubing to the drain (discharge) hose
connecon of the control valve.
The drain (discharge) hose may be elevated up to 1.8 meters providing the run does not
exceed 4.6 meters and water pressure at the soener is not less than 2.76 bar.
Where the drain (discharge) hose is elevated but empes into a drain below the level of the
control valve, form an 18cm loop at the far end of the line so that the boom of the loop is
level with the drain hose connecon. This will provide an adequate siphon tap.
Where the drain (discharge) empes into an overhead sewer line, a sink-type U-bend trap
must be used.
Secure the end of the drain (discharge) hose to prevent it from moving.
Drinking Water
When ng your Water Soener, allowance should be made for at least one drinking water
tap that is not fed by the Water Soener. Where praccal this should be at the kitchen sink
but a Ulity Room or other suitable alternave will suce.
It is recommended that people on a low sodium diet should not drink arcially soened
water. Water used for mixing infant powder for babies must only be taken from unsoened
water as soened water contains an increased level of sodium which will not be accounted
for in the infant formula.
Brine Line Connecons
Check the connecons taking care not to over-ghten. Be sure that the regeneraon line is
secure and free from air leaks.
Electrical Connecon
For added safety the Scalemaster 100/200 series control operates on low voltage via a
plug in transformer. Use only the transformer supplied with the soener.
ANY ELECTRICAL WORK REQUIRED TO INSTALL A MAINS POWER SUPPLY FOR
THE WATER SOFTENER SHOULD ONLY BE CARRIED OUT BY A FULLY
QUALIFIED ELECTRICIAN.