EasyManua.ls Logo

schmersal AZM-Y-8P-IO - User Manual

schmersal AZM-Y-8P-IO
2 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
EN
Operating instructions. . . . . . . . . . . . .pages 1 to 2
Original
AZM-Y-8P-IO
AZM-Y-A-8P-IO
Operating instructions
Y-adapter and terminating plug
EN
1
Product description
Purpose
The Y-adapter AZM-Y-8P-IO makes it possible to connect in series
electronic solenoid interlocks and sensors in the series AZM, MZM
and RSS.
For this purpose the safety channels are connected in series. The
IN inputs as well as the diagnostic outputs OUT are connected in
parallel. The terminating plug AZM-Y-A-8P-IO supplies the safety
channels with the operating voltage. M12 cable extensions can be
used for the wiring. Please note that voltage losses could occur (due
to cable length, cable section, voltage drop / solenoid interlock). This
aspect limits the maximum number of solenoid interlocks and sensors
connected in series.
The electrical connection may only be carried out by
authorised personnel in a de-energised condition.
Technical data
Operating voltage SD device: 24 VDC (–15%/+10%)
Rated operating voltage adapter: 30 VDC
Maximum operating current device connection: 1 A
Fuse rating for the supply cable (cable protection): 4 A
Ambient temperature T
u
: – 25 ºC … + 75 °C
Recommended tightening torque:
- Connection side: 1.0 Nm
- For the fastening screws: 1.2 Nm
x.000 / 03.2018 / v.A. - 103025640-EN / A / 2018-03-13 / AE-Nr. -
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
The information contained in this operating instructions manual is
provided without liability and is subject to technical modifications.
Wiring example
AZM-Y-A-8P-IOAZM-Y-8P-IO AZM-Y-8P-IO AZM-Y-8P-IO
12
12
12
AZM-Y-8P-IO AZM-Y-8P-IO AZM-Y-8P-IO AZM-Y-A-8P-IO
Question and Answer IconNeed help?

Do you have a question about the schmersal AZM-Y-8P-IO and is the answer not in the manual?

Summary

Product Description

Purpose of Y-Adapter

Explains the Y-adapter's function for connecting solenoid interlocks and sensors in series, and parallel connection of diagnostic outputs.

Technical Data

Electrical Specifications

Details operating voltage, max current, fuse rating, and ambient temperature for the Y-adapter and terminating plug.

Mechanical Specifications

Specifies recommended tightening torque for connection and fastening screws.

Wiring and Connection Examples

Wiring Diagram Overview

Illustrates the wiring example for the Y-adapter and terminating plug with connected devices.

Connection Example Details

Provides detailed connection diagrams showing pin assignments for the Y-adapter and terminating plug.

schmersal AZM-Y-8P-IO Specifications

General IconGeneral
Brandschmersal
ModelAZM-Y-8P-IO
CategoryAdapter
LanguageEnglish