1
AZM300
Operating instructions
Solenoid interlock
EN
1. About this document
1.1 Function
This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety switchgear. The operating
instructions must be available in a legible condition and a complete
version in the vicinity of the device.
1.2 Target group: authorised qualified personnel
All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical specifications for the
selection, mounting and integration of the components.
1.3 Explanation of the symbols used
Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.
1.4 Appropriate use
The products described in these operating instructions are developed
to execute safety-related functions as part of an entire plant or machine.
It is the responsibility of the manufacturer of a machine or plant to
ensure the correct functionality of the entire machine or plant.
The safety switchgear must be exclusively used in accordance with
the versions listed below or for the applications authorised by the
manufacturer. Detailed information regarding the range of applications
can be found in the chapter "Product description".
1.5 General safety instructions
The user must observe the safety instructions in this operating
instructions manual, the country specific installation standards as well
as all prevailing safety regulations and accident prevention rules.
Content
1 About this document
1.1 Function ..............................................1
1.2 Target group: authorised qualied personnel..................1
1.3 Explanation of the symbols used ...........................1
1.4 Appropriate use ........................................1
1.5 General safety instructions ...............................1
1.6 Warning about misuse ...................................2
1.7 Exclusion of liability .....................................2
2 Product description
2.1 Ordering code .........................................2
2.2 Special versions........................................2
2.3 Comprehensive quality insurance to 2006/42/EC ..............2
2.4 Purpose ..............................................2
2.5 Technical data .........................................3
2.6 Safety classication .....................................4
3 Mounting
3.1 General mounting instructions .............................4
3.2 Manual release ........................................5
3.3 Emergency exit -T/-T8 or emergency release -N...............5
3.4 Mounting with mounting plate .............................5
3.5 Dimensions ...........................................6
3.6 Actuator and accessories.................................6
4 Electrical connection
4.1 General information for electrical connection..................7
5 Operating principle, actuator coding and latching force adjustment
5.1 Magnet control .........................................7
5.2 Mode of operation of the safety outputs......................7
5.3 Actuator coding ........................................7
5.4 Adjustment of the latching force............................7
6 Diagnostic function
6.1 Diagnostic-LEDs .......................................7
6.2 Solenoid interlock with conventional diagnostic output ..........7
6.3 Solenoid interlock with serial diagnostic function SD............9
7 Set-up and maintenance
7.1 Functional testing......................................10
7.2 Maintenance .........................................10
8 Disassembly and disposal
8.1 Disassembly..........................................10
8.2 Disposal .............................................10
9 Appendix
9.1 Wiring examples ......................................10
9.2 Wiring conguration and connector accessories ..............11
10 EU Declaration of conformity
x.000 / 04.2020 / v.A. - 103001171-EN / O / 2020-04-20 / AE-Nr. 12264
EN
Operating instructions. . . . . . . . . . . .pages 1 to 12
Original
Question and Answer IconNeed help?

Do you have a question about the schmersal AZM300 and is the answer not in the manual?

Summary

About this document

General safety instructions

Instructs users to observe safety regulations, country-specific standards, and accident prevention rules.

Technical data

Electrical data - Safety outputs

Specifies electrical parameters for the safety outputs, including voltage, current, and leakage.

Safety classification

Interlocking function classification

Details the safety classification for the interlocking function according to standards like ISO 13849-1.

Guard locking function classification

Specifies the safety classification for the guard locking function, including PL and SIL ratings.

Mounting

General mounting instructions

Provides general guidelines for mounting, including observance of standards and alignment.

Mounting of the solenoid interlock and the actuator

Refers to specific instructions for mounting the interlock and actuator, ensuring proper fit.

Emergency exit -T;-T8 or emergency release -N

Actuator and accessories

Electrical connection

Operating principle, actuator coding and latching force adjustment

Actuator coding

Details the teach-in procedure for individually coded solenoid interlocks and actuators.

Adjustment of the latching force

Explains how to adjust the latching force by turning the rotary handle to different positions.

Diagnostic function

Solenoid interlock with serial diagnostic function SD

Details serial diagnostic functionality using SD cable, serial input/output, and evaluation via PLC.

Set-up and maintenance

Functional testing

Lists essential checks before and during functional testing of safety components.

Disassembly and disposal

Summary

About this document

General safety instructions

Instructs users to observe safety regulations, country-specific standards, and accident prevention rules.

Technical data

Electrical data - Safety outputs

Specifies electrical parameters for the safety outputs, including voltage, current, and leakage.

Safety classification

Interlocking function classification

Details the safety classification for the interlocking function according to standards like ISO 13849-1.

Guard locking function classification

Specifies the safety classification for the guard locking function, including PL and SIL ratings.

Mounting

General mounting instructions

Provides general guidelines for mounting, including observance of standards and alignment.

Mounting of the solenoid interlock and the actuator

Refers to specific instructions for mounting the interlock and actuator, ensuring proper fit.

Emergency exit -T;-T8 or emergency release -N

Actuator and accessories

Electrical connection

Operating principle, actuator coding and latching force adjustment

Actuator coding

Details the teach-in procedure for individually coded solenoid interlocks and actuators.

Adjustment of the latching force

Explains how to adjust the latching force by turning the rotary handle to different positions.

Diagnostic function

Solenoid interlock with serial diagnostic function SD

Details serial diagnostic functionality using SD cable, serial input/output, and evaluation via PLC.

Set-up and maintenance

Functional testing

Lists essential checks before and during functional testing of safety components.

Disassembly and disposal

schmersal AZM300 Specifications

General IconGeneral
Operating Voltage24 VDC
Protection RatingIP67
Voltage Rating24 VDC
Safety CategoryCategory 4
Locking PrincipleMagnetic
Number of Safety Contacts2
Rated Current0.25 A
Connection TypeCable with connector
StandardsEN ISO 13849-1, EN 60947-5-3
Current Rating0.25 A
Actuator TypeMagnetic
MountingSurface mount