EasyManua.ls Logo

Schulz MSV 20 MAX - User Manual

Schulz MSV 20 MAX
2 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
B
42
suction
Position
TABLE1-TORQUE ESPECIFICATIONS FOR BOLTS
lbf.in
215
53
348
143
19
294
4-9
10
19
33
21-30
24
N.m
25
6
40.5
16.7
2.2
34.2
9
2
3
9
4
5
6
1 1.1
7
8
17
9
10
11
7
12
13
14
40
38
B
B
A
A
39
18
28
15
16
24
23
41
21
22
7
7
20
19
7
36
37
25
13
34
35
30
33
24
32
7
31
7
29
19
7
27
26
30
Detail of the
assembly of
HP/LP oil rings
Detail of the assembly LP cylinder cover
See picture
cylinder cover
T6
T6
T4
T1
T1
T2
T3
T4
T5
T1
T2
T3
T5
T5
T3
COMPRESSOR MSV 20 MAX
TWO STAGES
175 PSIG
TWO STAGES
175 PSIG
TECHNICAL DATA
TECHNICAL DATA
BARE PUMP PARTS
BARE PUMP PARTS
CAST IRON INDUSTRIAL COMPRESSORS
DISPLACEMENT
cfm
MAX. PRESSURE
psig
MOTOR
hp
BELT OIL CAP.
in.qtl
WEIGHT
in lbs
DISCHARGE
SIZE
MOTOR PULLEY
2 poles 4 poles
RPM
20 175 1050 5
1-A
2-A*
* Optional
1.061.0 94.8 1/2'' NPT
128 2165.04 8.5
mm mminch inch
MSV 20 MAX
MODEL
Flywheel (1-A)
Flywheel (2-A)
Oil seal
6206 bearing
M8 x 1,25 x 20 hex. head screw
Flange
6207 bearing
Gasket kit
Key
Crankshaft
M5 x 0,8 x 20 head bolt
Labyrinth cover
Crankcase
1/4" plug
3/4" oil level sight
Needle bearing
HP connecting rod with needle bearing
HP Ø 2" piston
HP 2" ring kit
M10 x 1,5 x 25 hex. head bolt
HP 2" cylinder
HP valve plate kit
HP 2" valve plate
HP 2" cylinder cover
M8 x 1,25 x 30 hex. head bolt
Intercooler
LP connecting rod
LP Ø 90mm piston
LP 90mm ring kit
LP 90mm cylinder
LP valve plate kit
LP 90mm valve plate
LP 90mm cylinder cover
M6 x 1,0 x 45 Allen hex. head bolt
Air filter
Filter element
5/8" ring kit
NPT 1/2" x 5/8" elbow
Crankcase breather tube kit
NPT 1/8"x1/4" elbow
1/8"x1/4" straight connection
HP 1/8" ASME safety valve
LP 1/8" ASME safety valve
Pulley ø 216 mm (1A) - not shown
Pulley ø 128 mm (1A**) - not shown
Pulley ø 218 mm (2A) - not shown
CODE CODE
QTY QTY
DENOMINATION DENOMINATION
709.1062-0
709.1107-0
023.0265-0
019.0004-8
*
709.1056-0
019.0005-6
830.0776-0/NA
709.0163-3
830.0778-0
*
20028001
709.1231-0
003.0028-4
830.0775-0
019.0064-0
830.0783-0
830.0786-0
830.0781-0
*
709.1057-0
830.0782-0
830.0785-0
709.1332-0
*
709.1229-0
709.1068-0
016.0042-0
830.0780-0
709.1058-0
830.0779-0
830.0784-0
709.1232-0
*
007.0116-0
007.0118-0
830.0603-0
003.0294-0
830.0340-5
003.0005-5
003.0054-3
022.0215-0
022.0177-0
709.1168-0
709.1150-0
709.1270-0
01
01
01
01
06
01
01
01
01
01
01
01
01
02
01
01
01
01
01
08
01
01
01
01
10
01
01
01
01
01
01
01
01
01
01
01
01
02
01
01
01
01
01
01
01
01
No. No.
1
1.1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
-
-
-
* Part available in the market - not sold by Schulz.
** The standard motor pulley is supplied with a standard hole.
Note: HP = high pressure LP = low pressure
APRIL/06 025.0305-0/Rev.01
TC 168
COMPRESSOR MSV 20 MAX
ft.lb
18
4.4
29
12
1.6
24.5
T6
37
Question and Answer IconNeed help?

Do you have a question about the Schulz MSV 20 MAX and is the answer not in the manual?

Summary

Technical Data

Torque Specifications for Bolts

Bare Pump Parts

Installation and Operation Instructions

Installation and Location

Guidance on placing the compressor in a well-ventilated, dust-free area, ensuring proper airflow and maintenance access.

Electrical Connection

Instructions for connecting the compressor to the power supply, adhering to country-specific low voltage electrical standards.

Operation: Initial Start Procedure

Steps for the first start, including checking oil level and running the compressor for 10 minutes to ensure lubrication.

Operation: Start

Procedure for starting the compressor, running it for 10 minutes to achieve optimal lubrication and pressure.

Maintenance

Daily Checks

Visual inspection, oil level check, draining moisture, and checking for unusual vibration or noise.

Weekly Checks

Cleaning intake filters, checking V-belt tension, external cleaning, and testing the ASME safety valve.

Monthly Checks

System air leakage check, pressure switch operation verification, and checking for oil contamination.

Quarterly Checks

Replacing air filter element, tightening bolts/nuts, and checking oil more frequently in dirty environments.

Annually Checks

Testing/calibrating pressure switch, gauge, safety valve, and inspecting/cleaning valve plates.

Lubrication Schedule

Recommended oil change intervals: after 8 hours, 40 hours, then every 200 hours or 60 days.

Recommended Lubricant Oils

Guidance on selecting appropriate industrial oils based on ambient temperature for Schulz air compressors.

Limited Warranty

Summary

Technical Data

Torque Specifications for Bolts

Bare Pump Parts

Installation and Operation Instructions

Installation and Location

Guidance on placing the compressor in a well-ventilated, dust-free area, ensuring proper airflow and maintenance access.

Electrical Connection

Instructions for connecting the compressor to the power supply, adhering to country-specific low voltage electrical standards.

Operation: Initial Start Procedure

Steps for the first start, including checking oil level and running the compressor for 10 minutes to ensure lubrication.

Operation: Start

Procedure for starting the compressor, running it for 10 minutes to achieve optimal lubrication and pressure.

Maintenance

Daily Checks

Visual inspection, oil level check, draining moisture, and checking for unusual vibration or noise.

Weekly Checks

Cleaning intake filters, checking V-belt tension, external cleaning, and testing the ASME safety valve.

Monthly Checks

System air leakage check, pressure switch operation verification, and checking for oil contamination.

Quarterly Checks

Replacing air filter element, tightening bolts/nuts, and checking oil more frequently in dirty environments.

Annually Checks

Testing/calibrating pressure switch, gauge, safety valve, and inspecting/cleaning valve plates.

Lubrication Schedule

Recommended oil change intervals: after 8 hours, 40 hours, then every 200 hours or 60 days.

Recommended Lubricant Oils

Guidance on selecting appropriate industrial oils based on ambient temperature for Schulz air compressors.

Limited Warranty

Schulz MSV 20 MAX Specifications

General IconGeneral
BrandSchulz
ModelMSV 20 MAX
CategoryCompressor
LanguageEnglish