26
NOZZLES - PRESSURE - COLLECTOR TABLE
SWG A 23 - SWG R 23
Type of
Gas
Furnace
Useful
[kW]
Thermal
Capacity
[kW]
Pressure
Press.
[mbar]
Ø
Nozzles
[mm]
Nozzles
no.
Ø Col-
lector
[mm]
Pressure
minimum
[mbar]
Pressure
operating
[mbar]
Consumption
min.
Consumption
max.
Nat. gas (G20)
9,9 - 22,9 11,5 - 25,5 20 1,25 11 - 3,2 14,6 1,22 m³/h 2,70 m³/h
Propane (G31)
9,9 - 22,9 11,5 - 25,5 37 0,85 11 - 6,0 28,6 0,89 kg/h 1,98 kg/h
SWG A 23 P
Type of
Gas
Furnace
Useful
[kW]
Thermal
Capacity
[kW]
Pressure
Press.
[mbar]
Ø
Nozzles
[mm]
Nozzles
no.
Ø Col-
lector
[mm]
Pressure
minimum
[mbar]
Pressure
operating
[mbar]
Consumption
min.
Consumption
max.
Nat. gas (G20)
9,9 - 22,9 11,5 - 25,5 20 1,25 11 - 3,3 14,6 1,22 m³/h 2,70 m³/h
Propane (G31)
9,9 - 22,9 11,5 - 25,5 37 0,85 11 - 6,0 28,6 0,89 kg/h 1,98 kg/h
SWG R 18 - SWG C 18
Type of
Gas
Furnace
Useful
[kW]
Thermal
Capacity
[kW]
Pressure
Press.
[mbar]
Ø
Nozzles
[mm]
Nozzles
no.
Ø Col-
lector
[mm]
Pressure
minimum
[mbar]
Pressure
operating
[mbar]
Consumption
min.
Consumption
max.
Nat. gas (G20)
7,8 - 18,5 9 - 20,5 20 1,25 11 - 1,7 10 0,95 m³/h 2,17 m³/h
Propane (G31)
7,8 - 18,5 9 - 20,5 37 0,75 11 - 6,3 31,3 0,70 kg/h 1,59 kg/h
SWG C 16: parameter HP = 17 (CH) - for DHW VALUES see SWG 24 C
Type of
Gas
Furnace
Useful
[kW]
Thermal
Capacity
[kW]
Pressure
Press.
[mbar]
Ø
Nozzles
[mm]
Nozzles
no.
Ø Col-
lector
[mm]
Pressure
minimum
[mbar]
Pressure
operating
[mbar]
Consumption
min.
Consumption
max.
Nat. gas (G20)
10,1- 14,6 11,5 - 16,0 20 1,35 11 - 2,3 4,6 1,22 m³/h 1,52 m³/h
Propane (G31)
10,1- 14,6 11,5 - 16,0 37 0,85 11 - 6,1 12,3 0,89 kg/h 1,24 kg/h
SWG R 24 - SWG C 24
Type of
Gas
Furnace
Useful
[kW]
Thermal
Capacity
[kW]
Pressure
Press.
[mbar]
Ø
Nozzles
[mm]
Nozzles
no.
Ø Col-
lector
[mm]
Pressure
minimum
[mbar]
Pressure
operating
[mbar]
Consumption
min.
Consumption
max.
Nat. gas (G20)
10,1- 24,6 11,5 - 26,5 20 1,35 11 - 2,3 12,8 1,22 m³/h 2,80 m³/h
Propane (G31)
10,1- 24,6 11,5 - 26,5 37 0,85 11 - 6,1 33,5 0,89 kg/h 2,06 kg/h
SWG R 28 - SWG C 28
Type of
Gas
Furnace
Useful
[kW]
Thermal
Capacity
[kW]
Pressure
Press.
[mbar]
Ø
Nozzles
[mm]
Nozzles
no.
Ø Col-
lector
[mm]
Pressure
minimum
[mbar]
Pressure
operating
[mbar]
Consumption
min.
Consumption
max.
Nat. gas (G20)
10,2- 28,0 11,5 - 30,1 20 1,30 1-3 - 2,0 13,3 1,22 m³/h 3,18 m³/h
Propane (G31)
10,2- 28,0 11,5 - 30,1 37 0,85 13 - 4,4 29,0 0,89 kg/h 2,34 kg/h
SWG C 32
Type of
Gas
Furnace
Useful
[kW]
Thermal
Capacity
[kW]
Pressure
Press.
[mbar]
Ø
Nozzles
[mm]
Nozzles
no.
Ø Col-
lector
[mm]
Pressure
minimum
[mbar]
Pressure
operating
[mbar]
Consumption
min.
Consumption
max.
Nat. gas (G20)
11,6 31,6 13,5 - 34,5 20 1,30 15 - 1,8 13,3 1,43 m³/h 3,65 m³/h
Propane (G31)
11,6- 31,6 13,5 - 34,5 37 0,85 15 - 4,4 29,0 1,05 kg/h 2,68 kg/h
SWG C 24 P
Type of
Gas
Furnace
Useful
[kW]
Thermal
Capacity
[kW]
Pressure
Press.
[mbar]
Ø
Nozzles
[mm]
Nozzles
no.
Ø Col-
lector
[mm]
Pressure
minimum
[mbar]
Pressure
operating
[mbar]
Consumption
min.
Consumption
max.
Nat. gas (G20)
10,1- 24,7 11,5 - 26,5 20 1,35 11 - 2,3 12,80 1,22 m³/h 2,80 m³/h
Propane (G31)
10,1- 24,7 11,5 - 26,5 37 0,85 11 - 5,8 32 0,89 kg/h 2,06 kg/h
SWG C 28 P
Type of
Gas
Furnace
Useful
[kW]
Thermal
Capacity
[kW]
Pressure
Press.
[mbar]
Ø
Nozzles
[mm]
Nozzles
no.
Ø Col-
lector
[mm]
Pressure
minimum
[mbar]
Pressure
operating
[mbar]
Consumption
min.
Consumption
max.
Gas nat. (G20) 10,2- 28,1 11,5 - 30,1 20 1,30 13 - 2,0 13,3 1,22 m³/h 3,18 m³/h
Propano (G31) 10,2- 28,1 11,5 - 30,1 37 0,85 13 - 4,4 29 0,89 kg/h 2,34 kg/h
SWG C 32 P
Type of
Gas
Furnace
Useful
[kW]
Thermal
Capacity
[kW]
Pressure
Press.
[mbar]
Ø
Nozzles
[mm]
Nozzles
no.
Ø Col-
lector
[mm]
Pressure
minimum
[mbar]
Pressure
operating
[mbar]
Consumption
min.
Consumption
max.
Nat. gas (G20)
12,2 - 32,3 13,5 - 34,5
20 1,30
15
-
1,8
13,3
1,43 m³/h 3,65 m³/h
Propane (G31)
12,2 - 32,3 13,5 - 34,5
37 0,85
15
-
4,4
29
1,05 kg/h 2,68 kg/h
Theburnerpressuresstatedinthefollowingtablemustbecheckedafter3minutesofoperationandreferto,formodelsS(TFS),withcombustionchamberclosed.