090-252 Rev A
2-9
2.2.2.4.2.4 Option 4, Profile Fixed Time
This option allows the user to start a profile at a certain hour each day.
The user may set the hour and minute. Note that a profile will only be
started at this time if the system is in Auto and Program Enable is set
to a “2”, as described above. The type of profile to be started (regular
or Top Scan) is controlled by the profile type, as described above.
2.2.2.4.3 Option 3, Time
This option of the "Edit System Parameters" menu allows the user to set
the system time. The user is prompted to enter year, month, day, hour,
minute and second.
2.2.2.4.4 Option 4, Software Version
Selecting the Software Version option while connected to the control
module causes three software versions to be displayed. The first is for the
control module itself, the second is for the signal conditioning card (a sub-
component of the control module), and the third is the software version of
the Hand Held PC.
2.2.2.5 Option 5, Modbus (Edit Modbus Parameters)
Choosing option 5 on the Edit Parameters menu brings up the "Edit Modbus
Parameters" submenu. This menu allows access to all the parameters
governing Modbus communications.
2.2.2.5.1 Option 1, Level
This option allows the user to set scaling information for the transmission
of level and position. High and low values must be specified defining the
range of values to be reported. In addition, scaling must be chosen (i.e. 0
to 9999, -32000 to 32000, 0 to 65000, etc.).
2.2.2.5.2 Option 2, Temperature
This option allows the user to set scaling information for the transmission
of temperature to the host computer. High and low values must be
specified defining the range of values to be reported. In addition, scaling
must be chosen (i.e. 0 to 9999, -32000 to 32000, 0 to 65000, etc.).
2.2.2.5.3 Option 3, Density
This option allows the user to set scaling information for the transmission
of density information to the host computer. High and low values must be