Page 9
Page 9
SPECIFICATIONS
ELECTRONIC CUBER MODEL EC 105
NOTE
. With the unit in "built-in" conditions, the ice production is gradually reduced in respect to the
levels shown in the graf, up to a maximum of 10% at room temperatures higher than 32
°
C.
The daily ice-making capacity is directly related to the condenser air inlet temperature, water
temperature and age of the machine.
To keep your SCOTSMAN CUBER at peak performance levels, periodic maintenance checks must
be carried out as indicated on page 41 of this manual.
Important operating requirements:
MIN MAX
Air temperature 10°C (50°F) 40°C (100°¯F)
Water temperature 5°C (40°F) 40°C (100°F)
Water pressure 1 bar (14 psi) 5 bar (70 psi)
Electr. voltage
variations from
voltage rating
specified on
nameplate -10% +10%
ice making capacity
50
48
46
44
42
40
38
36
34
32
30
Kg.
32 °C
AIR COOLED MODELS
WATER TEMPERATURE
AMBIENT TEMPERATURE
ICE PRODUCED PER 24 HRS.
°C
10
21
32
38
WATER COOLED MODELS
27 21 15 10
50
48
46
44
42
40
38
36
34
32
30
Kg.
32 °C
WATER TEMPERATURE
AMBIENT TEMPERATURE
ICE PRODUCED PER 24 HRS.
32
38
27 21 15 10
°C
10
21