EasyManua.ls Logo

Scotsman MVP606 - Ice Storage Bin Maintenance; Condenser and Filter Cleaning

Scotsman MVP606
33 pages
Print Icon
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 33
Page 33
15. Locate water level sensor. Squeeze catches
together and pull up to remove sensor. Wash
metal surfaces of sensor with ice machine scale
remover solution.
16. Mix a solution of sanitizer.
Note: A possible sanitizing solution may
be made by mixing 1 ounce of liquid
household bleach with 2 gallons of warm
(35-45
°
C) potable water.
17. Thoroughly wash all surfaces of the ice
thickness sensor, water level sensor, curtain and
water distributor with the sanitizer solution.
18. Wash all interior surfaces of the freezing
compartment, including evaporator cover and
right side panel liner with the sanitizer solution.
19. Return water level sensor, ice thickness
sensor, water distributor and curtain to their
normal positions.
20. Push and hold the clean button to drain the
reservoir. Push and release the clean button
again and when the purge valve indicator light
goes out, immediately pour the remaining
cleaning solution into the reservoir.
21. Circulate the sanitizer solution for 10 minutes,
then push and release the Clean button.
22. Allow the water system to be flushed of
sanitizer for at least 20 minutes, then push and
release the Off button.
23. Return the evaporator cover and front panel
to their normal position and secure with the
original fasteners.
24. Push and release the On button to resume
ice making.
Ice Storage Bin
1. Remove and discard all ice.
2. Mix a solution of 7 ounces of Scotsman
Clear 1 ice machine scale remover in 84 ounces
of potable water and wash all interior surfaces of
the ice storage bin to remove any mineral scale
build up. Pour excess cleaner solution into the
bin’s drain.
3. Mix a solution of sanitizer and thoroughly
wash all interior surfaces of the ice storage bin.
Pour excess sanitizer solution into the bin’s drain.
Air cooled condenser filter
1. Pull air filter(s) forward from side panel.
2. Wash the dust and grease off the filter.
3. Return it to its original position.
Do not operate the machine without the filter
in place except during cleaning.
Air cooled condenser
If the machine has been operated without a filter
the air cooled condenser fins will need to be
cleaned.
They are located under the fan blades. The
services of a refrigeration technician will be
required to clean the condenser.
Exterior Panels
The front and side panels are durable stainless
steel. Fingerprints, dust and grease will require
cleaning with a good quality stainless steel
cleaner.

Related product manuals