16
Install a hand valve near the machine to control
the water supply.
DRAINS
AIR-COOLED MODELS: There is one 20 mm.
diameter sump drain fitting at the back of the
cabinet. Insulations in high humidity areas is
recommended. The ideal drain receptacle
would be a trapped and vented floor drain.
STORAGE BIN: A separate gravity type drain
needs to be run, similar to the air-cooled sump
drain. Insulation of this drain line is
recommended.
FOR THE ELECTRICIAN
ELECTRICAL CONNECTIONS
The unit comes equipped with an electrical cord
for power supply. The lead wires must be
connected to an electrical plug that
corresponds to the local electrical codes and
requirements or to a separate two poles
disconnect box with opening to the contacts of
about 3 millimeters. The disconnect box should
be placed close to the selected ice maker
location to be easily and prompt reached.
Undersized wiring or improperly installed
electrical circuit will result in major problems
and malfunctions.Voltage variations should not
exceed ten percent.
1) Plug receptacle
2) Electrical plug
3) Water inlet
4) Shut-off valve
5) Water filter
6) Water inlet line
7) Water outlet line
8) Bin water outlet line
9) Open vented water drain
- All plumbing and electrical
connections must be made by licensed plumbers
and electricians, this one must follow the
electrical specifications printed on the ice maker
nameplate.
: All SCOTSMAN Cubers require a
neutral wire and a solid earth ground wire to
prevent possible severe Electrical Shock Injury
to individuals or extensive damage to
equipments.